Fluke 6105A Electrical Power Quality Calibrator
The Fluke 6105A Electrical Power Quality Calibrator is a precision instrument for calibrating power quality analyzers and meters. It delivers stable, accurate AC voltage, current, phase angle, frequency, and harmonics to ensure the performance and accuracy of power quality measurement devices. Ideal for calibration labs and field service, the 6105A is essential for maintaining reliable power quality monitoring systems.
- Model
- Fluke 6105A
- Calibration
- Available on request
- Price
- $71,880
- Status
- In stock
- RFQ ref
- 6105A
This unit
The Fluke 6105A Electrical Power Quality Calibrator is a master reference standard that generates stable, high-precision AC voltage, current, phase angle, frequency, and harmonic signals for calibrating power quality analyzers, meters, and related measurement devices. Voltage generation accuracy reaches 0.005% (50 ppm), with one-year sinusoidal energy accuracy to 0.007% (66 ppm). The instrument delivers up to 1008 V pure sinusoidal output with 50 VA sourcing capacity and up to 21 A sinusoidal current at 0.005% (50 ppm) accuracy.
Phase adjustment resolution is 1 milli-degree, with phase performance accuracy of 2.3 milli-degrees for single-phase and 5 milli-degrees between multi-phase voltages. Frequency operates from 45 Hz to 65 Hz. The 6105A replaces the Fluke 6100A and meets IEC 61000-4 series standards, including IEC 61000-4-30 and IEC 61000-4-34 compliance.
It generates complex power quality phenomena including flicker, harmonics, dips, swells, interharmonics, and fluctuating harmonics, with independent interharmonic generation at user-definable levels up to 9 kHz. Optional configurations support 50 A current output or 80 A auxiliary units. Compliance voltage up to 14 V peak is available from current outputs.
Ideal for calibration laboratories and field service operations requiring precision power quality monitoring system maintenance.
Technical Specifications
- Voltage output: 0–1008 V, pure sinusoidal
- Current output: 0–21 A, pure sinusoidal (50 A and 80 A options available)
- Frequency range: 45 Hz to 65 Hz
- Voltage generation accuracy: <0.005% (50 ppm)
- Current generation accuracy: <0.005% (50 ppm)
- One-year sinusoidal energy accuracy: 0.007% (66 ppm)
- Phase adjustment resolution: 1 milli-degree (10 micro-radian)
- Phase accuracy (single-phase): 2.3 milli-degrees
- Phase accuracy (multi-phase): 5 milli-degrees between phase voltages
- Voltage sourcing capacity: 50 VA
- Current compliance voltage: Up to 14 V peak
- Interharmonic frequency range: Up to 9 kHz
Key Features
- Master reference standard for power quality measurement device calibration
- Pure sinusoidal voltage and current generation with minimal distortion
- Independent interharmonic generation at user-definable levels and frequencies
- Mix-and-match harmonic and interharmonic waveforms on voltage or current signals
- Generation of flicker, dips, swells, and fluctuating harmonics
- IEC 61000-4 series standards compliance
Typical Applications
- Calibration laboratory operations
- Field service maintenance of power quality monitoring systems
- Verification of power quality analyzer performance
- Testing and validation of power meters
Compatibility & Integration
- Direct replacement for Fluke 6100A Electrical Power Calibration Standard
- Meets IEC 61000-4-30 and IEC 61000-4-34 requirements
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 45 Hz to 65 Hz | Voltage / Current Range: 0–1008 V, 0–21 A (50 A and 80 A options available) |
Fluke 6105A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 6105A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Fluke 6105A price
This Fluke 6105A is listed at $71,880. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 6105A calibration cost
NIST-traceable calibration for the Fluke 6105A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →