Ametek / VTI Instruments / VXI Technology 70-0155-000 Blank Front Panel
Ametek / VTI Instruments / VXI Technology VXI Modules.
- Model
- Ametek / VTI Instruments / VXI Technology 70-0155-000
- Calibration
- Available on request
- Price
- $45
- Status
- In stock
- RFQ ref
- 70-0155-000
This unit
The Ametek / VTI Instruments / VXI Technology 70-0155-000 is a blank front panel engineered to occupy unused module slots in VXIbus mainframes. It maintains a clean, flush front panel finish while preserving system structural integrity and airflow management in unpopulated slot positions. This panel integrates directly into VXI Technology SMIP II Series modular signal switching systems, where it fills empty slots within high-density, reconfigurable switch architectures.
Technical Specifications
- Product Type: Blank Front Panel
- Manufacturer: Ametek / VTI Instruments / VXI Technology
- Model Number: 70-0155-000
- Form Factor: Standard VXIbus card slot configuration
- Installation Method: Slides into module slot groove and secures flush with mainframe front panel
Key Features
- Designed for VXIbus mainframe compatibility
- Fills unused slots to eliminate unsightly gaps in modular systems
- Supports flexible, high-density switch configurations in SMIP II Series installations
- Maintains consistent front panel appearance across mixed module deployments
- Aids in thermal management and airflow integrity within enclosed mainframe designs
Typical Applications
- VXIbus test system configuration where not all available slots are populated with active switching modules
- SMIP II Series modular signal switching systems requiring aesthetic and functional slot coverage
- Mixed-module test architectures combining active switches with unpopulated positions
Compatibility & Integration The 70-0155-000 integrates with VXIbus mainframes and is specifically engineered for the SMIP II Series family of modular signal switching systems. These systems employ flexible, high-density plug-in module architectures that allow custom switch configurations through module combination and intermixing. The blank panel ensures unused slots remain covered and do not compromise system presentation or operational performance. Original manufacturing by Ametek, VTI Instruments, and VXI Technology has reached End-of-Life status. Third-party suppliers continue to stock and support this component for legacy system maintenance and expansion.
Ametek / VTI Instruments / VXI Technology 70-0155-000 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Ametek / VTI Instruments / VXI Technology 70-0155-000. Calibration covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Ametek / VTI Instruments / VXI Technology 70-0155-000 faults: relay contact wear, DAC/ADC drift, VXI backplane connector oxidation. Common faults include relay contact wear, DAC or ADC gain drift, and VXI backplane edge connector oxidation. Most modules are repaired at the component level with full post-repair verification in a C-size or D-size mainframe.
Ametek / VTI Instruments / VXI Technology 70-0155-000 price
This Ametek / VTI Instruments / VXI Technology 70-0155-000 is listed at $45. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Ametek / VTI Instruments / VXI Technology 70-0155-000 calibration cost
NIST-traceable calibration for the Ametek / VTI Instruments / VXI Technology 70-0155-000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers all module-specific parameters per manufacturer datasheet, output accuracy and linearity, frequency accuracy, and VXI register and trigger bus compliance. Turnaround is 1 to 3 business days after receipt. See full calibration details →