Anritsu ML2419A – Power Meter Range Calibrator

Anritsu Calibration Equipment. Accuracy: ±1.2 % per year, Accuracy: <.

Model
Anritsu ML2419A
Calibration
Available on request
Price
$2,400
Status
In stock
RFQ ref
ML2419A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu ML2419A is a power meter range calibrator engineered to verify measurement channels in Anritsu ML2400A Series Power Meters. It delivers a stable, accurate reference signal at 50 MHz and 0 dBm (1.000 mW) to ensure measurement reliability in metrology and calibration facilities. Remote control via the power meter enables fully automated calibration workflows.

Technical Specifications Reference Signal Output

Nominal frequency: 50 MHz

Reference power level: 0 dBm / 1.000 mW

Output connector: Front panel 50 Ω precision N-type (female)

Output accuracy: ±1.2 % per year

Frequency accuracy: <1 % Signal Channel Ranges The ML2419A provides voltage testing across five overlapping ranges, spanning +7 dB to −70 dB relative to 1.0 V:

Range 1: +7 dB to −12 dB (DC voltage)

Range 2: −11 dB to −28 dB (DC voltage)

Range 3: −25 dB to −44 dB (250 Hz chopped voltage)

Range 4: −41 dB to −58 dB (250 Hz chopped voltage)

Range 5: −56 dB to −70 dB (250 Hz chopped voltage) Ranges 3, 4, and 5 employ 250 Hz voltage chopping to minimize offset and drift errors. The power meter applies a 309.5 gain factor in chopped-mode operation. Testing covers maximum and minimum power levels per range, except Range 5, which tests at maximum and 30 % of maximum. Adjacent ranges overlap, allowing single-voltage testing at boundary dB levels. Connectivity & Control

Sensor A connector: 12-pin circular precision connector for 1.5 m power sensor cables

Remote operation via power meter menu system Power Supply

AC input: 115 V / 60 Hz or 230 V / 50 Hz (selectable)

Input range: 90–132 V or 180–264 V, 47–63 Hz

Maximum consumption: 6 VA

Fuse: 0.1 A, 250 V, antisurge (T)

Front-panel LED indicates AC power status

Safety category: Installation (Overvoltage) Category II, Insulation Category I Physical Dimensions

Width: 213 mm (8.39 in)

Height: 88 mm (3.46 in)

Depth: 250 mm (9.84 in)

Weight: 2.2 kg (4.84 lb)

Key Features

Five calibration ranges with overlapping coverage from +7 dB to −70 dB

Dual operational modes: DC voltage (Ranges 1–2) and 250 Hz chopped voltage (Ranges 3–5)

N-type RF output for direct sensor calibration reference

Full remote control integration with ML2400A Series power meters

Compact benchtop form factor

Typical Applications

Power meter range verification and calibration traceability

Sensor signal channel testing across dynamic power ranges

Automated calibration procedures in standards labs

Periodic validation of RF power measurement systems

Compatibility & Integration The ML2419A integrates directly with Anritsu ML2400A Series Power Meters via the 12-pin sensor connector and can be controlled entirely through the power meter's menu interface, eliminating the need for separate control hardware.

Specifications

ParameterValue
Frequency Range50 MHz | Power Range (dBm): 0 dBm reference output
signal channels +7 dBm to −70 dBm relative to 1.0 V | Voltage / Current Range47–63 Hz, 90–132 V or 180–264 V AC

Anritsu ML2419A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu ML2419A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Anritsu ML2419A price

This Anritsu ML2419A is listed at $2,400. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu ML2419A calibration cost

NIST-traceable calibration for the Anritsu ML2419A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →