Agilent/Keysight N1298C

Agilent / Keysight Power Supply Accessories. Voltage / Current Range: 0-210 V DC, 0-3 A DC, Bandwidth: 2 kHz nominal (1 A/3 A ranges).

Model
Agilent / Keysight N1298C
Calibration
Available on request
Price
$750
Status
In stock
RFQ ref
N1298C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight N1298C is a low-noise filter accessory engineered to enhance the performance of Keysight B2960B Series precision source/measure units. It reduces voltage and current noise across both sourcing and measurement functions, delivering output characteristics comparable to linear power supplies. The filter supports DC voltage outputs to 210 V and current outputs to 3 A, with an output resistance of 0.3 Ω nominal in 2-wire configuration.


Technical Specifications



  • Maximum Output Range: 210 V DC; 3 A DC

  • Output Resistance (2-wire): 0.3 Ω nominal

  • Maximum Capacitive Load: 1 mF

  • Voltage Noise (Sourcing): 5 μVpp (0.1 to 10 Hz); 30 μVrms (10 to 20 MHz)

  • Current Noise (Sourcing): 60 pApp (0.1 to 10 Hz); 450 nArms (10 to 1 MHz)

  • Small Signal Bandwidth: 2 kHz nominal (1 A/3 A ranges); 800 Hz nominal (100 mA range)

  • Output Connectors: Banana jacks


Key Features



  • Reduces noise floor for both voltage and current sourcing

  • Supports bipolar voltage and current operation across wide ranges

  • 4-wire connection capability for accurate remote sourcing and measurement

  • Drives capacitive loads up to 1 mF

  • 0.3 Ω output resistance minimizes voltage drop at measurement points


Compatibility & Integration The N1298C is designed specifically for integration with the Keysight B2961B/B2962B low-noise power sources and compatible B2960B Series SMUs. When connected, the filter significantly reduces the residual noise floor of the measurement system, enabling precision applications requiring ultra-clean signal sourcing.

Specifications

ParameterValue
Voltage / Current Range0-210 V DC, 0-3 A DC

Agilent / Keysight N1298C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight N1298C. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight N1298C price

This Agilent / Keysight N1298C is listed at $750. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight N1298C calibration cost

NIST-traceable calibration for the Agilent / Keysight N1298C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →