Agilent/Keysight N8930A Autoranging System DC Power Supply 1000V 30A

Agilent / Keysight DC Power Supplies. Voltage: ** 1, Current: ** 30 A, Voltage: ** 0 V.

Model
Agilent / Keysight N8930A
Calibration
Available on request
Price
$8,500
Status
In stock
RFQ ref
N8930A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight N8930A is a, autoranging, single-output DC power supply designed for demanding Automated Test Equipment (ATE) applications. It has a flexible power output with a maximum of 10 kW, providing a wide range of voltage and current combinations at full power, unlike traditional power supplies with fixed output characteristics. This autoranging capability allows the N8930A to function as multiple power supplies in one unit, enhancing flexibility and efficiency in test system development. The unit is housed in a compact 3U rackmount chassis, optimizing space utilization in test racks. For applications requiring higher power, multiple N8930A units can be paralleled using the built-in master/slave control to operate as a single, larger power supply capable of delivering over 100 kW, with individual units programmed as one.

Technical Specifications General Features * Product Series: N8900 Series

  • Product Type: Autoranging System DC Power Supply
  • Output Configuration: Single Output
  • Autoranging Capability: Yes
  • Form Factor: 3U Rackmount Chassis
  • Built-in Measurements: Voltage and Current
  • Front Panel Operation: Accessible via menu system with knobs and keypad DC Output Ratings * Maximum Output Power: 10,000 W (10 kW)
  • Maximum Output Voltage: 1,000 V
  • Maximum Output Current: 30 A
  • Minimum Output Voltage: 0 V
  • Minimum Output Current: 0 A Input Power Requirements * Input Voltage: 208 VAC
  • Minimum Supply Voltage: 187 V
  • Maximum Supply Voltage: 229 V Performance Specifications * **Programming Accuracy

Voltage:** Approximately 0.1% of full-scale

  • **Programming Accuracy

Current:** Approximately 0.2% of full-scale

  • Power Factor: > 0.99 Protection Features * Overvoltage Protection (OVP): Yes
  • Overcurrent Protection (OCP): Yes
  • Overtemperature Protection (OTP): Yes Interfaces * Standard Interfaces: GPIB, Ethernet/LAN (LXI Core), USB 2.0, Analog
  • Remote Access: Supported via built-in web server and standard interfaces Environmental Specifications * Operating Temperature Range: 0°C to 45°C Physical Specifications * Dimensions (L x W x H): 660 mm x 483 mm x 133 mm (approximate, based on standard rack unit height)
  • Weight: 26.4 kg Compatibility and Expandability * Parallel Operation: Capable of paralleling with up to ten identical units (same model number) for increased power output
  • Master/Slave Control: Built-in for seamless programming of paralleled units Documentation * Available Documents: Data Sheets, User Guides, Service Manuals, Technical Overviews, Product Fact Sheets, Application Notes, Demos, Help Files Why Choose Aumictech for the Keysight N8930A? At Aumictech, we specialize in supplying high-end power supply equipment. Whether you need solid power for complex ATE systems, flexible voltage and current configurations for product design validation, or reliable performance for laboratory testing, our team ensures the Keysight N8930A delivers maximum performance for your application.

Agilent / Keysight N8930A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight N8930A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Agilent / Keysight N8930A price

This Agilent / Keysight N8930A is listed at $8,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight N8930A calibration cost

NIST-traceable calibration for the Agilent / Keysight N8930A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents