Lambda / TDK / EMI NV-175

Lambda / TDK / EMI AC Power Supply. Voltage: 90–264VAC, Current: 16ms at 90VAC input, Accuracy: ±1%.

Model
Lambda / TDK / EMI NV-175
Calibration
Available on request
Price
$150
Status
In stock
RFQ ref
NV-175
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The TDK-Lambda NV-175 is a configurable AC/DC power supply for industrial, commercial, and medical applications. Delivering 175W, 180W, or 200W depending on configuration, this compact 3" × 5" module integrates into host equipment with high efficiency up to 90% and power density suitable for sensitive electronics. Universal input acceptance (90–264VAC, 47–63Hz, also 440Hz with reduced PFC) combined with active power factor correction and 1–5 configurable output channels makes the NV-175 adaptable to diverse system requirements.


Technical Specifications



  • Output Power: 175W, 180W, or 200W (configuration dependent; 5V Channel 1 models typically limited to 175W)

  • Input Voltage: 90–264VAC, 47–63Hz; 440Hz capable with reduced PFC

  • Number of Outputs: 1 to 5 configurable outputs

  • Efficiency: Up to 90%

  • Power Factor Correction: Active PFC, EN61000-3-2 compliant (0.97 typical)

  • Inrush Current: 16ms at 90VAC input

  • Turn-On Time: 1.5s max at 90VAC and 100% rated output power

  • Total Regulation: 1% including line, load, and cross-regulation (0–100% load change)

  • Voltage Accuracy: ±1%; ±4% for Channel 4 'T'/'F' types; +4%/−3% for other Channel 4 outputs

  • Ripple & Noise: 105% of rated output

  • Overvoltage Protection: 120–130% of nominal output (CH1 & CH2); resets via AC line cycling

  • Overtemperature Protection: Yes

  • Isolation Input to Ground: 2.3kVDC (1 × MOOP)

  • Isolation Input to Output: 4.3kVDC (2 × MOOPs; medical reinforced version available)

  • Isolation Output to Ground: 200VDC


Key Features



  • Remote sense capability on CH1 & CH2 (0.5V max compensation)

  • DC Good signal on CH1 only (90% nominal ±5%)

  • Remote on/off control with TTL-level switching

  • No minimum load requirement

  • Field-installable output connectors


Typical Applications Industrial control systems, medical instrumentation, commercial equipment requiring multi-rail isolated power conversion with high reliability and compact integration.

Specifications

ParameterValue
Frequency Range440Hz capable, 47–63Hz | Voltage / Current Range: 90–264VAC input

Lambda / TDK / EMI NV-175 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lambda / TDK / EMI NV-175. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lambda / TDK / EMI NV-175 price

This Lambda / TDK / EMI NV-175 is listed at $150. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lambda / TDK / EMI NV-175 calibration cost

NIST-traceable calibration for the Lambda / TDK / EMI NV-175 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents