Advantest R3755A PCI Card Network Analyzer, 300MHz

Advantest R3755A,Compact PCI card-based network analyzer ideal for embedded systems and automated test setups. Operates at 300 MHz for targeted frequency analysis. Provides accurate vector measurements for impedance, gain, and reflection. Suited for board-level diagnostics, education, and OEM applications requiring space-saving and cost-effective RF analysis.

Model
Advantest R3755A
Calibration
Available on request
Price
$2,370
Status
In stock
RFQ ref
R3755A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R3755A is a half-size PCI card network analyzer that brings vector measurement capability to embedded test systems and automated benchtop setups. Operating from 10 kHz to 300 MHz with 1 mHz resolution, it delivers precise characterization of impedance, gain, reflection, and frequency response across four measurement channels. The compact form factor (190 × 126 × 20 mm) and low power draw (15 W maximum) make it ideal for board-level diagnostics, educational labs, and OEM integration where space and cost constraints are critical.


Technical Specifications

Signal Source

  • Frequency range: 10 kHz to 300 MHz

  • Frequency resolution: 1 mHz

  • Frequency accuracy: ±20 ppm (±1 ppm with OPT.20)

  • Output level: 0 to −30 dBm (10 kHz–1 MHz); +18 to −43 dBm (1 MHz–300 MHz)

  • Output resolution: 0.1 dB per step

  • Output connector: SMA (female), 50 Ω Receiving Section

  • Frequency range: 10 kHz to 300 MHz

  • Average noise floor: −70 dBm at 1 kHz RBW

  • Resolution bandwidth: 10 Hz to 15 kHz (1, 1.5, 2, 3, 4, 5, 7-step selection)

  • Input connector: SMA (female), 50 Ω Measurement Engine

  • Channels: 4

  • Parameters: A/R (R internally connected)

  • Formats: Log/Linear amplitude, phase, complex (real/imaginary), Z, R, X, Y, G, B

  • Calibration: Normalize, Full Call (Open/Short/Load)

  • Max measurement points: 1601 per segment

  • Sweep speed: 50 μsec/point minimum (15 kHz RBW) Electrical

  • Power supply: +5 VDC (5 W), +3.3 VDC (5 W), +12 VDC (1 W), −12 VDC (1 W)

  • Total consumption: ≤15 W Physical

  • Form factor: Half-size PCI card

  • Dimensions: 190 W × 126 H × 20 D mm

  • Mass: ≤1 kg


Key Features



  • 1 mHz frequency resolution over 300 MHz span

  • Four parallel measurement channels with independent A/R configuration

  • Arbitrary sweep segmentation with settable RBW and dwell time

  • Full 3-element calibration capability (Open/Short/Load)

  • Parallel I/O interface (8-bit output, 4-bit input, C-MOS logic)


Typical Applications Board-level network analysis, component characterization, antenna impedance measurement, educational laboratory testing, and OEM instrument integration.


Compatibility & Integration Requires 32-bit, 5 V, half-size PCI slot. Supports Windows XP (32-bit), Vista (32-bit), 7 (32/64-bit), and 10 (64-bit). Development via Visual Studio or Visual Basic/C++ 2008, or Visual Basic/C++ 6.0. Ambient temperature at card location must not exceed +55 °C.

Specifications

ParameterValue
Frequency Range10 kHz to 300 MHz | Power Range (dBm): '+18 to −43 dBm (1 MHz–300 MHz)
0 to −30 dBm (10 kHz–1 MHz) | Voltage / Current Range'+12 VDC @ 1W, +3.3 VDC @ 5W, +5 VDC @ 5W, −12 VDC @ 1W

Advantest R3755A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R3755A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R3755A price

This Advantest R3755A is listed at $2,370. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R3755A calibration cost

NIST-traceable calibration for the Advantest R3755A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents