Rockwell / Allen-Bradley TLS-GD2 Power to Lock Guard Locking Switch

Rockwell / Allen-Bradley Industrial Controllers & PLCs.

Model
Rockwell / Allen-Bradley TLS-GD2
Calibration
Available on request
Price
$110
Status
In stock
RFQ ref
TLS-GD2
View cart

This unit

The Rockwell/Allen-Bradley TLS-GD2 is a tongue-operated guard locking interlock switch designed to prevent access to hazardous machinery until power isolation is confirmed. This positive-mode safety device maintains guard integrity during equipment operation and delayed-stop scenarios. The TLS-GD2 is available in power-to-lock and power-to-release configurations, with maximum holding force of 2000 N and peak force of 2600 N using steel bolts.


Technical Specifications

Switch Operation

  • Actuation: Tongue-operated, positive mode

  • Locking configurations: Power-to-lock (TLS-2 GD2) or power-to-release (TLS-1 GD2, TLS-3 GD2)

  • Maximum holding force (Fzh): 2000 N (450 lb) with steel bolts

  • Maximum force (Fmax): 2600 N (585 lb) with steel bolts

  • Mechanical life: 1,000,000 operations

  • Electrical life: 1,000,000 operations Electrical Contacts

  • Contact sets: Five total

  • Safety contacts: Normally closed (N.C.) with direct opening action

  • Auxiliary contacts: Normally open (N.O.) for monitoring

  • Typical configurations: 2 N.C. safety with 1 N.O. auxiliary; 3 N.C. safety with 2 N.O. auxiliary (TLS-1 & -2); 4 N.C. safety with 1 N.O. auxiliary (TLS-3)

  • Contact rating (440G-TLS*): AC-15 A600 at 240V/3A or 120V/6A; DC-13 N150 at 125V/2.2A

  • Minimum switching: 3 mA / 18V Solenoid Specifications

  • Voltage options: 24V AC/DC, 110V AC, 110V AC/DC, 230V AC/DC

  • Power consumption: 7W, 100% ED


Key Features



  • High ingress protection suitable for washdown environments

  • Multiple contact configurations for safety and monitoring circuits

  • Compliance with EN 1088, EN 60947-5-1, ISO 13849-1:2006, IEC 62061, and ISO 14119

  • Certifications: CCC, CE, CUL, KC, UL

  • Applicable for ISO 13849-1:2006 and IEC 62061 safety integrity requirements


Typical Applications Guard locking on industrial machinery with extended stopping times; safeguarding during maintenance windows; equipment requiring fail-safe access control.


Compatibility & Integration Works with standard industrial control circuits. Contact configuration flexibility accommodates door position monitoring and lock status feedback requirements.

Specifications

ParameterValue
Voltage / Current Range110V AC, 110V AC/DC, 230V AC/DC solenoid