Keithley 2290-10 – 10KV Power Supply

Keithley High Voltage Power Supplies. Current: 1.000 mA DC (1 µA resolution), Accuracy: ±0.06% of full scale or ±(0.01% of setting + 2.5, Accuracy: ±1 V typical.

Model
Keithley 2290-10
Calibration
Available on request
Price
$4,500
Status
In stock
RFQ ref
2290-10
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 2290-10 is a high-voltage DC power supply delivering up to 10 kV with maximum output current of 1 mA. Engineered for precise high-voltage sourcing and monitoring, it serves applications including device breakdown testing, insulation testing, high-voltage resistivity measurements, and high-energy physics research. The unit combines low output noise with selectable filters to enable accurate low-level current measurements. Built-in interlock controls disable high-voltage output when safety interlocks are disengaged, and an optional protection module safeguards connected low-voltage instrumentation from voltage spikes during device breakdown events.

Technical Specifications Output Characteristics

Voltage Range: +100 V DC to +10,000 V DC (1 V resolution)

Maximum Output Current: 1.000 mA DC (1 µA resolution)

Output Ripple: 0.01% of full scale, VRMS (300 Hz–300 kHz); <1 VRMS maximum

With selectable filters: 1.0 mVRMS @ 1 kV, 2.0 mVRMS @ 3 kV, 3.0 mVRMS @ 5 kV Accuracy & Regulation

Voltage Set Accuracy: ±0.06% of full scale or ±(0.01% of setting + 2.5 V)

Voltage Display Accuracy: ±1 V typical; ±2 V maximum

Current Set Accuracy: 0.5% of full scale or 0.01% ±(0.01% + 2.5 µA)

Current Display Accuracy: ±1 µA typical; ±2 µA maximum

Line Regulation: 0.001% for ±10% line voltage change

Load Regulation: 0.04% for 100% load change (typical) Response & Stability

Rise Time (full load): <6 seconds to within 1 V of final value

Settling Time (full load): <4 seconds to within 1 V of final value

Discharge Time (full load): <1 second to under 10 V

Recovery Time: 120 ms for 40% load step change (typical)

Trip Response Time: <10 ms

Voltage Stability: ±0.01% per hour; <0.03% per eight hours

Temperature Drift: 50 ppm/°C (0° to 40°C, typical)

Output Stored Charge: <20 µC maximum

Current Limit Range: 0 to 105% of full scale

Trip Current Range: 10 µA to 105% of full scale

Key Features

Selectable output filters for noise reduction in sensitive measurements

Safety interlock system with optional protection module

IEEE-488 (GPIB) and RS-232 serial control

Analog control voltage input for external modulation

Power Rating: 75 W / 10 W

Typical Applications

High-voltage device breakdown testing

Component and insulation testing

High-voltage resistivity measurements

High-energy physics research

Compatibility & Integration Programming interfaces include IEEE-488 (GPIB) and RS-232, with analog control voltage input for system integration.

Specifications

ParameterValue
Voltage / Current Range'+100 V DC to +10, 0 to 1.000 mA DC, 000 V DC

Keithley 2290-10 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 2290-10. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Keithley 2290-10 price

This Keithley 2290-10 is listed at $4,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 2290-10 calibration cost

NIST-traceable calibration for the Keithley 2290-10 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →