Agilent/Keysight 34134A

Agilent / Keysight Laboratory Measurement Instruments. Current: 10 mA to 80 A across dual ranges (10 mA–2 A and, Current: 10 mA to 60 A across dual ranges (10 mA–1.5 A an, Bandwidth: DC to 8 kHz (–3 dB).

Model
Agilent / Keysight 34134A
Calibration
Available on request
Price
$1,250
Status
In stock
RFQ ref
34134A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight 34134A is an AC/DC DMM current probe that extends the current measurement capabilities of compatible digital multimeters without breaking the circuit. Using Hall sensor technology, this battery-powered clamp-on probe measures low DC or AC currents across industrial and automotive applications - ground currents, power supply ripple, and system current distribution. The narrow jaw design accommodates cable diameters to 11.8 mm, making it well-suited for densely wired environments.


Technical Specifications

Current Measurement

  • DC Current: 10 mA to 80 A across dual ranges (10 mA–2 A and 100 mA–80 A)

  • AC Current: 10 mA to 60 A across dual ranges (10 mA–1.5 A and 100 mA–60 A)

  • Bandwidth: DC to 8 kHz (–3 dB)

  • Output Signals: 1 V/A and 10 mV/A Accuracy & Noise

  • 1 V/A range: ±2% reading ±5 mA (10 mA–2 A DC; 10 mA–1.5 A AC); ±4% reading ±20 mA (500 mA–50 A DC/40 A AC); ±12% reading (50–80 A DC, 0–60 A AC)

  • 10 mV/A range: noise 15 µV (DC–1 Hz), 140 µV (1 Hz–10 kHz), 180 µV (0–100 kHz)

  • Slew rate: 120 mV/µs (1 V/A); 5.5 mV/µs (10 mV/A)

  • Phase shift: 1° (DC–65 Hz) Physical & Environmental

  • Dimensions: 67 × 231 × 36 mm; Weight: 330 g (with battery)

  • Operating temperature: 0 to 50 °C; Storage: –30 to 80 °C

  • Operating humidity: 0 to 85% RH (at 0–50 °C)

  • Working voltage: 600 V CAT III

  • Case protection: IP20; Mechanical shock: 100 G (IEC 68-2-27); Vibration per IEC 68-2-6 (10–55 Hz, 0.15 mm amplitude)

  • Output: Right-angle shrouded banana plugs; 1.5 m cable


Key Features



  • Hall sensor–based design eliminates circuit interruption during measurement

  • Dual output scaling (1 V/A and 10 mV/A) for flexible integration

  • Fiberglass-reinforced polycarbonate housing rated IP20

  • Battery-powered operation for portability


Compatibility & Integration Direct compatibility confirmed with Keysight 34460A, 34461A, 34401A, 34410A, 34411A, and L4411A DMM models. Output termination via standard banana plugs enables integration with other instruments accepting analog voltage inputs.

Agilent / Keysight 34134A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 34134A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 34134A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Agilent / Keysight 34134A price

This Agilent / Keysight 34134A is listed at $1,250. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 34134A calibration cost

NIST-traceable calibration for the Agilent / Keysight 34134A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →