Advantest R6441A – Digital multimeter

Advantest Laboratory Measurement Instruments. Frequency Range: 20 Hz to 20 kHz (AC measurement), Voltage / Current Range: DC: 20 mV to 1000 V; AC: 200 mV to 700 V; DC Current: 20 mA to 10 A.

Model
Advantest R6441A
Calibration
Available on request
Price
$879
Status
In stock
RFQ ref
R6441A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R6441A is a 4.5-digit digital multimeter engineered for precision measurement across DC and AC voltage, and DC current applications in manufacturing, R&D, and quality control environments. The instrument features dual-channel input capability with dual display operation, integrating-type measurement circuitry, and selectable auto or manual range switching. A 7-segment electron-ray indicator tube provides clear readings at sampling rates up to 80 samples/second.


The R6441A forms the baseline of the R6441 series, with enhanced variants offering expanded AC measurement (R6441B) and specialized current measurement capabilities (R6441C).


Technical Specifications

DC voltage measurement spans 20 mV to 1000 V with resolution down to 1 µV on the 20 mV range and accuracy from ±0.04% ±5 digits (20–200 mV) to ±0.07% ±10 digits (1000 V). Input impedance reaches 1 GΩ or more across 20 mV–200 V ranges. AC voltage measurement covers 200 mV to 700 V at 10 µV to 100 mV resolution with frequency response from 20 Hz to 20 kHz (±0.2% ±30d at 45 Hz to 20 kHz). DC current ranges span 20 mA to 10 A with 1 µA to 1 mA resolution. Maximum display readings reach 199999 at 2.5 samples/second or 1999 at 80 samples/second. Input method is floating type; maximum allowable DC voltage is 1100 V continuous. AC voltage measurement handles up to 800 Vrms with 1100 V peak, includes 300 Hz to 100 kHz filter, and delivers response time of approximately 4 seconds.

Key Features



  • Dual-channel input with dual display for flexible measurement workflows

  • Integrating measurement method for noise rejection: ~120 dB normal mode, ~60 dB common mode (50/60 Hz)

  • Optional battery operation for field deployment (0–40°C operating range with battery)

  • Memory function preserves panel settings between sessions

  • Compact form factor: 212 (W) × 88 (H) × 310 (D) mm, 2.2 kg maximum

  • Power consumption ≤15 VA; operates on 90–250 V AC mains


Typical Applications Manufacturing test, quality assurance verification, laboratory research and development, field service and troubleshooting.

Specifications

ParameterValue
Frequency Range20 Hz to 20 kHz (AC measurement) | Voltage / Current Range: DC: 20 mV to 1000 V
AC200 mV to 700 V
DC Current20 mA to 10 A

Advantest R6441A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R6441A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest R6441A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Advantest R6441A price

This Advantest R6441A is listed at $879. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R6441A calibration cost

NIST-traceable calibration for the Advantest R6441A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →