Agilent / Keysight 86107A Precision Timebase Reference Module
Agilent / Keysight Clock & Timing Analyzers. Frequency Range: 2 to 48 GHz, Power Range (dBm): 16 dBm maximum, Voltage / Current Range: 0.2 – 1.5 Vpp input; maximum ±2 V.
- Model
- Agilent / Keysight 86107A
- Calibration
- Available on request
- Price
- $24,272
- Status
- In stock
- RFQ ref
- 86107A
This unit
The Agilent/Keysight 86107A Precision Timebase Reference Module delivers ultra-low jitter timing for high-speed signal characterization in the 86100 family oscilloscope platform. This plug-in module significantly improves timebase resolution and jitter performance, enabling precision measurements of electrical signals above 10 Gb/s and optical signals above 20 Gb/s.
Technical Specifications
Jitter Performance- Less than 100 fs RMS for frequencies greater than 4 GHz
- Less than 280 fs RMS for frequencies less than 4 GHz
- Overall jitter reduction of nearly one order of magnitude to less than 200 fs RMS Timebase Resolution
- Improved to 2 ps/division (5x enhancement over standard 10 ps/division) Input Signal Specifications
- Signal type: Synchronous clock, square wave to sine wave
- Amplitude: 0.2 – 1.5 Vpp
- Trigger range: 2 to 48 GHz (option-dependent)
- Maximum reference clock input: ±2 V (16 dBm)
- Connectors: 3.5 mm male (standard), 2.4 mm male (>25 GHz bandwidth) Bandwidth Options
- 15 GHz, 20 GHz, and 48 GHz configurations available Signal Analysis Capability
- Precision jitter analysis of electrical signals above 10 Gb/s
- Optical signal jitter analysis above 20 Gb/s
- Waveform capture to 40 Gb/s
Key Features
- Clock input options: 2.5/10 GHz (86107A-010), 10/20 GHz (86107A-020), 10/20/40 GHz (86107A-040)
- DC blocking capacitor option (86107A-021): 45 MHz – 26.5 GHz
- Commercial calibration certificate available (UK6 option)
- Precision timebase configuration via N1060A or 86107A setup dialog
- Operates in Free Run mode or with Pattern Lock/Jitter Mode
Typical Applications
- High-speed digital design characterization
- Semiconductor device testing
- Telecommunications signal integrity analysis
- Aerospace and research timing applications
Compatibility & Integration Designed for the Agilent/Keysight 86100 family: 86100A/B/C/D Infiniium DCA and DCA-X Wide-Bandwidth Oscilloscopes. Reference clock connects directly to the module's front-panel Precision Timebase Input. When installed, the internal precision timebase (N1000A-PTB) is automatically disabled.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 2 GHz to 48 GHz (trigger range) |
| 10 GHz and 20 GHz (Option 20 clock input) | Voltage / Current Range | 0.2 to 1.5 Vpp |
Agilent / Keysight 86107A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 86107A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight 86107A price
This Agilent / Keysight 86107A is listed at $24,271.9. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 86107A calibration cost
NIST-traceable calibration for the Agilent / Keysight 86107A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →