Lambda / TDK / EMI LK351-FM

The Lambda LK351-FM is a reliable EMI filter designed to suppress electromagnetic interference in electronic devices. This filter ensures compliance with EMI regulations and enhances the overall performance and stability of electronic systems by reducing unwanted noise and interference.

Model
Lambda / TDK LK351-FM
Calibration
Available on request
Price
$340
Status
In stock
RFQ ref
LK351-FM
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Lambda / TDK / EMI LK351-FM is a 900 W DC power supply for automatic test equipment, laboratory, and industrial applications. It delivers 0–36 V DC at up to 25 A with exceptional line and load regulation of ≤0.01% of full scale (or 0.015% or 1 mV, whichever is greater), ensuring stable output for precision measurement and component testing. The unit accepts 85–265 V AC single-phase input and operates across 47–63 Hz, making it suitable for global installations.


Technical Specifications

Output Performance

  • Voltage: 0–36 V DC

  • Current: 0–25 A

  • Power: 900 W

  • Line Regulation: ≤0.01% of full scale or 0.015% or 1 mV whichever is greater (105–132 VAC input)

  • Load Regulation: ≤0.01% of full scale or 0.015% or 1 mV whichever is greater (no load to full load)

  • Ripple and Noise: ≤10 mV RMS or <1 mVrms or 500 µV RMS

  • Transient Response: ≤1 ms (50–100% load change)

  • Temperature Coefficient: 0.015%/°C Programming Accuracy

  • Voltage: ≤0.1% of rated output

  • Current: ≤0.2% of rated output Input Specifications

  • AC Input: 105–132 VAC, 47–63 Hz (derate output current by 10% for 50 Hz operation)

  • Constant Current Regulation: <10 mA or 0.1%, whichever is greater


Key Features



  • Front panel digital controls and display

  • Remote sensing for lead resistance compensation

  • Remotely programmable by voltage or resistance

  • Adjustable electronic current limiting

  • Overvoltage protection option (designated OV)

  • Thermostat-based overtemperature protection with automatic reset

  • Fuse-protected internal failures

  • Forced air cooling for high-power operation

  • 1U, 19-inch rack-mountable form factor (5-3/16" × 19" × 16-1/2")

  • Weight: 4.5 kg (10 lbs)

  • Brushed aluminum clear anodized panels with grey inlay


Typical Applications Automatic test equipment, laboratory power sourcing, industrial process control, and sensitive component characterization requiring tight regulation and low output noise.


Compatibility & Integration Rear-mounted terminal block connections. Remote sensing provisions enable precision regulation independent of load lead resistance. Programmable control supports integration with automated test systems and process monitoring equipment.

Specifications

ParameterValue
Voltage / Current Range0–25 A
Input85–265 V AC (single-phase), 0–36 V DC, 47–63 Hz

Lambda / TDK LK351-FM — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Lambda / TDK LK351-FM. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Lambda / TDK LK351-FM price

This Lambda / TDK LK351-FM is listed at $340. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Lambda / TDK LK351-FM calibration cost

NIST-traceable calibration for the Lambda / TDK LK351-FM is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents