Rod-L M100DC-5.5-5 DC Hipot Test Instrument
The Rod-L M100DC-5.5-5 is a DC Hipot Test Instrument designed for high-voltage DC testing. It ensures electrical safety and reliability by verifying insulation strength in various electronic components and devices. This instrument is ideal for quality control and compliance testing, providing accurate and dependable results.
- Model
- Rod-L M100DC-5.5-5
- Calibration
- Available on request
- Price · starting from
- $490
- Status
- In stock
- RFQ ref
- M100DC-5.5-5
This unit
The Rod-L M100DC-5.5-5 is a DC Hipot Test Instrument that performs dielectric withstand testing and concurrent ground continuity assessment on electrical and electronic devices. It subjects the device under test to user-adjustable DC voltages while monitoring insulation integrity and verifying effective leakage current shunting to earth ground. The instrument detects arc and overcurrent faults, shutting down within 2 milliseconds and rapidly discharging the DUT upon detection or test completion.
Built-in safety features include a chassis ground sense circuit, recessed start button, alarm light and tone, and internal shutdown circuitry. The M100DC-5.5-5 complies with UL, VDE, BSI, IEC, and CSA standards.
Technical Specifications
- Output Voltage Range: 0 to 5000 V DC, user-adjustable
- Voltage Control Resolution: 2.5 V
- Output Voltage Ripple: 1% at full load; 0.05% at zero current
- Regulation: 0.05% at full load
- Voltage Ramp Rate: 50 V/sec to 5000 V/sec, user-adjustable
- Output Current Range: 40 µA to 5 mA (10 mA optional)
- Current Resolution: 4 µA
- Ground Continuity Test: 0.5 Ω or less at 1.5 V AC
- Ground Continuity Reject Level: 0.1 to 0.5 Ω, adjustable to ±0.01 Ω
- Test Duration: 1 to 90 seconds, user-adjustable
- Initial Safety Pretest: 2 seconds before Hipot test initiation
- Line Input: 115/230 V AC, 44–66 Hz
- Maximum Power Draw: 360 W
- Accuracy: Better than 1%
- Operating Temperature: 0° to 50° C
- Fault Shutdown Time: Within 2 milliseconds
Key Features
- Concurrent ground continuity monitoring before and during Hipot test
- Arc detection with rapid fault shutdown
- Overcurrent detection and user-adjustable trip point control
- Rapid DUT discharge following test completion or fault event
- Chassis ground sense circuit and internal HV receptacle protection
- Front panel tester readiness, test status, and alarm indicators
- Rear panel controls for voltage ramp rate, test time, and overcurrent settings
Typical Applications Dielectric withstand validation for transformers, capacitors, cables, connectors, power supplies, medical devices, and industrial control equipment.
Compatibility & Integration Standard 115/230 V AC line input accommodates global industrial power systems. Front panel HV outlet accepts standard test leads and fixtures for DUT connection.
Specifications
| Parameter | Value |
|---|---|
| Voltage / Current Range | 0–5000 V DC output |
Rod-L M100DC-5.5-5 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Rod-L M100DC-5.5-5. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Rod-L M100DC-5.5-5 price
This Rod-L M100DC-5.5-5 is listed at $490. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Rod-L M100DC-5.5-5 calibration cost
NIST-traceable calibration for the Rod-L M100DC-5.5-5 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →