HP / Agilent 11848A Phase noise interface for the 3048A
The HP/Agilent 11848A is a phase noise interface module designed for use with the HP/Agilent 3048A phase noise measurement system. It enables accurate and efficient phase noise measurements of various signal sources.
- Model
- HP / Agilent 11848A
- Calibration
- Available on request
- Price
- $1,762
- Status
- In stock
- RFQ ref
- 11848A
This unit
The HP/Agilent 11848A Phase Noise Interface is a measurement module within the HP/Agilent 3048A Phase Noise Measurement System. It enables absolute residual, AM noise, and pulse measurements across a broad frequency span through integrated phase detectors, amplifiers, filters, and switches. The module supports both internal and external phase detection architectures, with internal reference oscillator outputs for system functional verification.
Technical Specifications
Frequency Coverage- Internal mixer: 5 MHz to 1.6 GHz
- With Option 201 (High Frequency Phase Detector): extends to 18 GHz without external down-conversion
- External phase detector input for out-of-range measurements Input Amplitude Requirements 5 MHz to 1.6 GHz operation:
- Left port: +15 dBm to +23 dBm
- Right port: 0 dBm to +23 dBm 1.2 GHz to 18 GHz (Option 201):
- Left port: +7 dBm to +10 dBm
- Right port: 0 dBm to +10 dBm Internal Reference Oscillator Outputs
- 10 MHz at +15 dBm with ±100 Hz tuning
- 10 MHz at +6 dBm with ±1 kHz tuning
- 350–500 MHz at +17 dBm with ±20 MHz tuning
- 400 MHz at −5 dBm (fixed tuning) Power Fuse ratings: 0.75 A (115 Vac, HP part 2110-0063); 0.5 A (230 Vac, HP part 2110-0012). Line power cable supplied per destination.
Key Features
- Supports two-port absolute residual measurements for phase noise characterization
- AM noise measurement capability integrated into measurement framework
- Built-in sources for pre-measurement functional verification of signal circuits
- GPIB programmable interface for automated control and integration
Typical Applications
- Phase noise and AM noise analysis of RF/microwave signal sources
- Residual phase noise measurement of oscillators and synthesizers
- Pulse modulation measurement analysis
Compatibility & Integration Designed as an integral module of the HP/Agilent 3048A Phase Noise Measurement System. Compatible with HP 3561A Dynamic Signal Analyzer for demodulated phase noise measurement. Works with HP 8662A and 8663A Synthesized Signal Generators. Accepts user-supplied external mixers. GPIB control requires National Instruments GPIB adapter.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 5 MHz to 1.6 GHz (internal mixer) |
| 5 MHz to 18 GHz (with Option 201) | Power Range (dBm) | '+15 dBm to +23 dBm (left port, 1.2–18 GHz), 1.2–18 GHz) |
| 0 dBm to +23 dBm (right port | Voltage / Current Range | 115 VAC / 230 VAC |
HP / Agilent 11848A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 11848A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
HP / Agilent 11848A price
This HP / Agilent 11848A is listed at $1,762. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 11848A calibration cost
NIST-traceable calibration for the HP / Agilent 11848A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →