Fluke 287 CAL True-RMS Electronics Logging Multimeter with TrendCapture

Fluke Laboratory Measurement Instruments. Voltage: 0–1000 V, Voltage: 0–1000 V True-RMS, Current: 0–10 A.

Model
Fluke 287 CAL
Calibration
Available on request
Price
$679
Status
In stock
RFQ ref
287 CAL
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Fluke 287 CAL is a True-RMS digital multimeter engineered for electronics troubleshooting, maintenance, and design verification in field and lab environments. It combines high-precision DC/AC voltage and current measurements with integrated data logging and graphical trend analysis. The CAL designation confirms factory calibration and documented accuracy upon delivery. TrendCapture technology instantly visualizes logged data to expose anomalies and performance drift without requiring PC downloads or post-analysis.

Technical Specifications Voltage & Current Measurements

DC Voltage: 0–1000 V, 0.025% basic accuracy

AC Voltage: 0–1000 V True-RMS, 0.4% basic accuracy, 100 kHz bandwidth

DC Current: 0–10 A, 0.05% basic accuracy

AC Current: 0–10 A True-RMS, 0.6% basic accuracy; 20 A for 30 seconds Extended Function Set

Resistance: 0–500 MΩ

Capacitance: 0–100 mF

Frequency measurement

Temperature measurement

Conductance: 50.00 nS

dBV/dBm measurement

Duty cycle and pulse width analysis

Diode testing and continuity beeper Logging & Trend Analysis TrendCapture graphically displays logged data in real time. The multimeter stores up to 15,000 recorded events across 180 hours of logging memory. Auto-hold thresholds trigger new events based on specified percentage changes in readings. 14x digital zoom enables detailed inspection of trend data. Multiple logging sessions operate independently without requiring data downloads to a PC. Display & Interface 1/4 VGA display with 50,000 counts resolution and white backlight. Simultaneous measurement display supports multiple data streams on-screen. Peak capture records transients as fast as 250 μs. Selectable AC filtering reduces noise on rapidly changing signals. Field measurements can be named and recalled. Multi-lingual interface supported.

Key Features

250 μs transient capture for spike and surge detection

180-hour unattended logging without external power draw

On-board help screens for rapid function reference

High-resolution display: 50,000 counts

Typical Applications Electronics maintenance and failure diagnosis; design verification under real-world load conditions; signal monitoring during equipment commissioning; transient and anomaly detection in power distribution systems.

Compatibility & Integration Powered by six AA alkaline batteries with 200 hours minimum logging runtime. Operating temperature range: -20 °C to 55 °C; storage: -40 °C to 60 °C. Relative humidity: 0–90% (0–37 °C); 0–65% (37–55 °C).

Specifications

ParameterValue
Frequency Range100 kHz (AC bandwidth) | Voltage / Current Range: 0–10 A DC/AC (20 A for 30 seconds), 0–1000 V DC/AC

Fluke 287 CAL — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Fluke 287 CAL. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Fluke 287 CAL faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Fluke 287 CAL price

This Fluke 287 CAL is listed at $679. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Fluke 287 CAL calibration cost

NIST-traceable calibration for the Fluke 287 CAL is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents