Fluke 287 CAL True-RMS Electronics Logging Multimeter with TrendCapture
Fluke Laboratory Measurement Instruments. Voltage: 0–1000 V, Voltage: 0–1000 V True-RMS, Current: 0–10 A.
- Model
- Fluke 287 CAL
- Calibration
- Available on request
- Price
- $679
- Status
- In stock
- RFQ ref
- 287 CAL
This unit
The Fluke 287 CAL is a True-RMS digital multimeter engineered for electronics troubleshooting, maintenance, and design verification in field and lab environments. It combines high-precision DC/AC voltage and current measurements with integrated data logging and graphical trend analysis. The CAL designation confirms factory calibration and documented accuracy upon delivery. TrendCapture technology instantly visualizes logged data to expose anomalies and performance drift without requiring PC downloads or post-analysis.
Technical Specifications Voltage & Current Measurements
DC Voltage: 0–1000 V, 0.025% basic accuracy
AC Voltage: 0–1000 V True-RMS, 0.4% basic accuracy, 100 kHz bandwidth
DC Current: 0–10 A, 0.05% basic accuracy
AC Current: 0–10 A True-RMS, 0.6% basic accuracy; 20 A for 30 seconds Extended Function Set
Resistance: 0–500 MΩ
Capacitance: 0–100 mF
Frequency measurement
Temperature measurement
Conductance: 50.00 nS
dBV/dBm measurement
Duty cycle and pulse width analysis
Diode testing and continuity beeper Logging & Trend Analysis TrendCapture graphically displays logged data in real time. The multimeter stores up to 15,000 recorded events across 180 hours of logging memory. Auto-hold thresholds trigger new events based on specified percentage changes in readings. 14x digital zoom enables detailed inspection of trend data. Multiple logging sessions operate independently without requiring data downloads to a PC. Display & Interface 1/4 VGA display with 50,000 counts resolution and white backlight. Simultaneous measurement display supports multiple data streams on-screen. Peak capture records transients as fast as 250 μs. Selectable AC filtering reduces noise on rapidly changing signals. Field measurements can be named and recalled. Multi-lingual interface supported.
Key Features
250 μs transient capture for spike and surge detection
180-hour unattended logging without external power draw
On-board help screens for rapid function reference
High-resolution display: 50,000 counts
Typical Applications Electronics maintenance and failure diagnosis; design verification under real-world load conditions; signal monitoring during equipment commissioning; transient and anomaly detection in power distribution systems.
Compatibility & Integration Powered by six AA alkaline batteries with 200 hours minimum logging runtime. Operating temperature range: -20 °C to 55 °C; storage: -40 °C to 60 °C. Relative humidity: 0–90% (0–37 °C); 0–65% (37–55 °C).
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz (AC bandwidth) | Voltage / Current Range: 0–10 A DC/AC (20 A for 30 seconds), 0–1000 V DC/AC |
Fluke 287 CAL — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 287 CAL. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 287 CAL faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 287 CAL price
This Fluke 287 CAL is listed at $679. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 287 CAL calibration cost
NIST-traceable calibration for the Fluke 287 CAL is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →