Advantest R6441B 4½‑Digit Multi‑functional Digital Multimeter

Advantest Laboratory Measurement Instruments. Frequency Range: 300 Hz to 100 kHz (AC voltage filter); frequency measurement capable, Power Range (dBm): dBm measurement capable (range not specified), Voltage / Current Range: 000 V, 20 mA to 10 A; AC: 200 mV to 700 V, DC: 20 mV to 1.

Model
Advantest R6441B
Calibration
Available on request
Price
$879
Status
In stock
RFQ ref
R6441B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R6441B is a 4½-digit digital multimeter engineered for precision measurement across DC, AC, and specialized test functions. Dual-channel input with dual display capability enables simultaneous measurements, making it ideal for R&D laboratories and production test environments. True RMS AC measurement, AC + DC combined measurements, and frequency analysis deliver versatility for complex signal characterization.


Battery operation extends field deployment capability.


Technical Specifications

Display & Sampling

  • 4.5-digit resolution

  • Maximum display: 199,999 (2.5 samples/second); 1,999 (80 samples/second)

  • Selectable sampling rates: 2.5 times/second or 80 times/second Voltage Measurement

  • DC ranges: 20 mV to 1,000 V

  • AC ranges: 200 mV to 700 V

  • DC accuracy: ±0.04% ±5d (20 mV–200 V); ±0.04% ±2d (2,000 mV)

  • AC accuracy: ±0.6% ±35d (20–45 Hz); ±0.2% ±30d (45 Hz–20 kHz); ±0.5% ±30d (20–30 kHz); ±4% ±50d (30–100 kHz)

  • Input impedance: ≥1 GΩ (20–200 mV); 10–11.1 MΩ ±1% (≥20 V); 1.1 MΩ ±10% AC input

  • DC maximum allowable: ±500 V; AC maximum: 800 Vrms / 1,100 Vpeak / 10⁷ VHz

  • Noise rejection: 60–120 dB normal mode (FAST/MID/SLOW)

  • AC crest factor: 3:1 at full scale Current Measurement

  • DC ranges: 20 mA to 10 A

  • AC ranges: True RMS capable

  • DC accuracy: ±0.2% ±5d (20 mA); ±0.6% ±5d (200 mA)

  • Terminal resistance: ≤1.5 Ω (20 mA–2,000 mA); ≤0.04 Ω (10 A)

  • Overcurrent protection: 0.5 A/250 V (low ranges); 15 A/250 V (10 A range) Additional Functions

  • Resistance, diode test, conductance, dBm measurement, frequency analysis

  • AC voltage filter: 300 Hz to 100 kHz

  • AC response time: ~4 seconds (typical)

  • Resolution: 1 µV to 100 mV (voltage); 1 µA to 1 mA (current)


Key Features



  • Dual-channel, dual-display architecture for parallel measurement workflows

  • True RMS AC + DC combined measurement capability

  • Frequency measurement and dBm analysis

  • Field-portable with battery operation option

  • Selectable sampling rates for dynamic range optimization

  • High input impedance (≥1 GΩ DC) minimizes circuit loading

  • Temperature-compensated accuracy (23 ± 5°C, ≤85% RH specification)


Typical Applications



  • Component and circuit characterization in R&D

  • In-circuit diagnostics and troubleshooting

  • Production line acceptance testing

  • AC/DC power supply validation

  • Frequency and conductance analysis


Compatibility & Integration Dual-channel design supports simultaneous measurement of related parameters, streamlining test sequences in both bench and automated environments.

Specifications

ParameterValue
Frequency Range300 Hz to 100 kHz (AC voltage filter)
frequency measurement capable | Power Range (dBm)dBm measurement capable (range not specified) | Voltage / Current Range: 000 V, 20 mA to 10 A
AC200 mV to 700 V, DC: 20 mV to 1

Advantest R6441B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R6441B. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest R6441B faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Advantest R6441B price

This Advantest R6441B is listed at $879. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R6441B calibration cost

NIST-traceable calibration for the Advantest R6441B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents