Keithley 2110-120 – 5½ Digit Dual-Display USB Multimeter
The Keithley 2110-120 is a 5½-digit dual-display digital multimeter (DMM) designed for benchtop use. It features a USB interface for easy data acquisition and control, a bright dual display for simultaneous viewing of measurements, and a wide range of measurement functions including voltage, current, resistance, frequency, and temperature. The DMM offers high accuracy and resolution for precise measurements in various electronic testing and measurement applications.
- Model
- Keithley 2110-120
- Calibration
- Available on request
- Price
- $475
- Status
- In stock
- RFQ ref
- 2110-120
This unit
The Keithley 2110-120 is a 5½-digit dual-display digital multimeter engineered for benchtop and portable bench applications. It combines 15 measurement functions with high-speed acquisition and exceptional accuracy, delivering up to 200 readings per second at full resolution via USB. The dual-line display enables simultaneous viewing of two independent measurements, streamlining data collection and analysis workflows in engineering, R&D, and production environments.
Technical Specifications Measurement Functions
15 measurement functions including DC/AC voltage, DC/AC current, resistance, capacitance, frequency, thermocouple, continuity, and diode measurement Math Operations
7 math functions: percentage, average, min/max, NULL, limits, mX+b, dB, and dBm Accuracy
DC voltage: 0.012% one-year basic accuracy
Resistance: 0.020% one-year basic accuracy up to 100 kΩ Measurement Speed
200 readings per second at 5½ digit resolution (USB)
50,000 readings per second at 4½ digit resolution
30,000 readings per second into buffer at 4½ digit setting Electrical Ranges
DC voltage: 0.1 V to 1000 V (1 kV max)
AC voltage: 0.1 V to 750 V (750 V max)
DC current: 10 mA to 10 A (10 A max)
AC current: 1 A to 10 A (10 A max)
Resistance: 100 Ω to 100 MΩ (0.1 GΩ max)
Frequency: 10 Hz to 300 kHz Input Protection
1000 V all ranges (2 W input)
Key Features
Dual-line display for simultaneous dual measurements
Rugged construction for durability in bench and portable use
USB 2.0 (TMC-compliant) with SCPI command support
Optional GPIB interface for system integration
Compatibility & Integration Includes LabVIEW and IVI drivers for automated test environments. Bundled software
KI-Tool and KI-Link - supports instrument control, data recording, and time-series plotting with Microsoft Word and Excel integration. USB cable, power cord, safety test leads, calibration certificate, and commissioning software included.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 10 Hz to 300 kHz | Voltage / Current Range: DC voltage: 0.1 V to 1000 V |
| AC voltage | 0.1 V to 750 V |
| DC current | 10 mA to 10 A |
| AC current | 1 A to 10 A |
Keithley 2110-120 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley 2110-120. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keithley 2110-120 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Keithley 2110-120 price
This Keithley 2110-120 is listed at $475. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley 2110-120 calibration cost
NIST-traceable calibration for the Keithley 2110-120 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →