Fluke 8010A Digital Multimeter
The Fluke 8010A is a solid and reliable digital multimeter designed for a wide range of electrical testing applications. It features a clear digital display, durable construction, and accurate measurement capabilities for voltage, current, and resistance. Ideal for electronics technicians and engineers.
- Model
- Fluke 8010A
- Calibration
- Available on request
- Price
- $75
- Status
- In stock
- RFQ ref
- 8010A
This unit
The Fluke 8010A is a 3.5-digit portable/benchtop digital multimeter engineered for precision electrical testing across DC and AC measurements. It delivers 0.1% basic DC accuracy using dual-slope integration to eliminate noise and provides true-RMS conversion for accurate non-sinusoidal waveform measurement. The instrument handles DC voltage from 100 µV to 1000 V, AC voltage from 10 mV to 750 V, DC current from 100 nA to 2 A, AC current from 10 µA to 2 A, and includes a dedicated 10 A AC/DC range.
Resistance measurement spans 100 mΩ to 20 MΩ, with conductance capability up to 10,000 MΩ equivalent resistance. The 3.5-digit LCD display provides autozero and autopolarity indication. True-RMS conversion handles crest factors of 1 to 1 and operates across 45 Hz to 50 kHz with typical ±3 dB response extending to 200 kHz.
Diode testing is supported through resistance ranges. Voltage overload protection reaches 1000 V DC or peak AC on all ranges, with transient protection to 6 kV for 10 microseconds. Current protection uses two in-series fuses (2 A/250 V and 3 A/600 V); the 10 A range is unfused.
Resistance/conductance inputs withstand up to 500 V without damage. Input impedance is 10 MΩ on all ranges. The instrument features normal mode rejection >60 dB at 60 Hz and common mode rejection >60 dB at DC, 50 Hz, and 60 Hz.
Response time is 1 second maximum within a range. AC line operation uses 90–132 V or 200–264 V at 50/60 Hz, consuming 2 W standard. Optional battery operation (8010A-01) provides 15–30 hours of use with 14-hour recharge time and low-battery indication at 1/2 hour remaining.
Technical Specifications
- Display: 3.5-digit LCD with autozero and autopolarity
- DC Voltage: 100 µV to 1000 V
- AC Voltage (True-RMS): 10 mV to 750 V (45 Hz to 50 kHz)
- DC Current: 100 nA to 2 A
- AC Current (True-RMS): 10 µA to 2 A, with dedicated 10 A range
- Resistance: 100 mΩ to 20 MΩ
- Conductance: Up to 10,000 MΩ equivalent resistance
- Diode Test: PN junction testing via resistance ranges
- Basic DC Accuracy: 0.1%
- Frequency Response: ±3 dB typical to 200 kHz; accuracy specified to 50 kHz
- Volt-Hz Product: 10⁷ max (200 V max @ 50 kHz)
- Input Impedance: 10 MΩ on all ranges
- Normal Mode Rejection: >60 dB at 60 Hz
- Common Mode Rejection: >60 dB at DC, 50 Hz, and 60 Hz (1 kΩ unbalanced)
- Overload Protection
Voltage: 1000 V DC or peak AC; transients to 6 kV for 10 µs
- Overload Protection
Current: Two in-series fuses (2 A/250 V, 3 A/600 V); 10 A range unfused
Overload Protection
Resistance/Conductance: Up to 500 V without damage
- Response Time: 1 second maximum within a range
- Power (AC line): 90–132 V or 200–264 V at 50/60 Hz; 2 W consumption
- Battery Option (8010A-01): 15–30 hours operation; 14-hour recharge time
Key Features
- Dual-slope integration eliminates noise floor
- True-RMS converter handles non-sinusoidal waveforms (crest factor 1 to 1)
- Fluke-manufactured true-RMS converter ensures accuracy across harmonically complex signals
- Clear LCD with dual indication modes
- Long-term calibration stability (1 year)
- 500 V resistance-mode overvoltage tolerance
- 6 kV transient protection on voltage inputs
Typical Applications
- Electronics technician troubleshooting and maintenance
- Power supply testing and verification
- Non-sinusoidal waveform measurement in switched circuits
- Field and laboratory AC/DC measurements
- Diode and junction testing
Compatibility & Integration Standard AC line operation with selectable voltage input. Fused current protection via dual in-series elements. Optional rechargeable battery operation enables extended portable use without line dependency.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 45 Hz to 50 kHz (specified accuracy) |
| ±3 dB response to 200 kHz | Voltage / Current Range | DC voltage: 100 µV to 1000 V |
| AC voltage | 10 mV to 750 V |
| DC current | 100 nA to 2 A |
| AC current | 10 µA to 2 A plus dedicated 10 A range |
Fluke 8010A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Fluke 8010A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Fluke 8010A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Fluke 8010A price
This Fluke 8010A is listed at $75. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Fluke 8010A calibration cost
NIST-traceable calibration for the Fluke 8010A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →