Yokogawa DLM5034 Mixed Signal Oscilloscope: 4-Channel, 350 MHz

The Yokogawa DLM5034 is a 4-channel, 350 MHz mixed signal oscilloscope. It combines the functionality of a digital oscilloscope and a logic analyzer, enabling the user to view both analog and digital signals simultaneously. This instrument is ideal for debugging and testing electronic circuits and systems. Its features include a large display, long memory, and a variety of triggering options.

Model
Yokogawa DLM5034
Calibration
Available on request
Price
$4,550
Status
In stock
RFQ ref
DLM5034
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Yokogawa DLM5034 is a 4-channel mixed-signal oscilloscope that merges digital oscilloscope and logic analyzer capabilities into a single instrument. It simultaneously captures analog signals across 4 channels and digital logic states across 16 or 32 bits, enabling comprehensive debugging of complex electronic systems. With 350 MHz bandwidth, 2.5 GS/s sample rate, and up to 1 Gpoint optional memory, the DLM5034 delivers extended capture windows and precise signal characterization.


The instrument features 12-bit vertical resolution (16-bit in High Resolution Mode), 14 configurable low-pass filters per channel, and vertical sensitivity down to 500 μV/div on 1 MΩ inputs. Vertical axis resolution reaches 12-bit maximum standard configuration, expandable to 16-bit in specialized modes.


Technical Specifications



  • Bandwidth: 350 MHz

  • Analog Channels: 4

  • Logic Channels: 16 bits (standard) or 32 bits (optional)

  • Sample Rate: 2.5 GS/s maximum

  • A/D Resolution: 8-bit

  • Vertical Resolution: 12-bit standard, 16-bit in High Resolution Mode

  • Vertical Sensitivity: 500 μV/div to 10 V/div (1 MΩ); 500 μV/div to 1 V/div (50 Ω)

  • Input Coupling: AC 1MΩ, DC 1MΩ, DC 50Ω

  • Input Impedance: 1 MΩ ±1.0%, 50 Ω ±1.0%

  • Maximum Input Voltage: 300 Vrms or 400 Vpeak (1 MΩ); 5 Vrms or 10 Vpeak (50 Ω)

  • Timebase: 1 ns/div to 500 s/div

  • Low-Pass Filters: 14 per channel, 8 kHz to 200 MHz cutoff

  • Waveform Memory: 50 Mpoints standard; up to 500 Mpoints or 1 Gpoint optional

  • History Memory: 100,000 waveforms


Key Features



  • Edge, pulse width, timeout, pattern, runt, rise/fall time, interval, and window triggering

  • Optional serial protocol triggers: UART, I2C, SPI, CAN, CAN FD, LIN, FlexRay, SENT, CXPI, PSI5

  • 29 automated waveform parameter measurements with simultaneous 30-measurement capability

  • Simultaneous 4-bus serial analysis at different speeds with dedicated logic decoding

  • Auto setup function for signal analysis and bus parameter optimization

  • Math channels and optional user-defined math functions

  • Extended search across long memory captures


Typical Applications



  • Power semiconductor circuit debugging and characterization

  • Electric vehicle motor control verification

  • Mechatronics system development and validation

  • Embedded systems protocol analysis

  • High-speed digital and analog signal simultaneous observation


Compatibility & Integration Optional power supply analysis module available. Logic inputs support decoding of I2C, SPI, UART, and SENT protocols.

Specifications

ParameterValue
Frequency Range350 MHz | Voltage / Current Range: 500 μV/div to 10 V/div (1 MΩ input)

Yokogawa DLM5034 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Yokogawa DLM5034. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Yokogawa DLM5034 price

This Yokogawa DLM5034 is listed at $4,550. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Yokogawa DLM5034 calibration cost

NIST-traceable calibration for the Yokogawa DLM5034 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →