Instek GFG-8215A Function Generator

The Instek GFG-8215A is a 15 MHz function generator that provides sine, square, triangle, and pulse waveforms. It features a frequency range of 0.1 Hz to 15 MHz, adjustable duty cycle, and a variety of output options. Ideal for educational and general-purpose testing applications.

Model
Instek GFG-8215A
Calibration
Available on request
Price
$185
Status
In stock
RFQ ref
GFG-8215A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Instek GFG-8215A is a 3 MHz function generator delivering precision signal generation across seven distinct frequency ranges from 0.3 Hz to 3 MHz. It generates sine, triangle, square, and ramp waveforms with dedicated TTL and CMOS outputs, making it suitable for bench testing, circuit development, and educational laboratory work. The instrument provides greater than 10 Vpp output into 50Ω loads with adjustable DC offset spanning -5 V to +5 V, dual-stage 20 dB attenuation, and variable attenuation control. Duty cycle adjustment operates from 20% to 80% with signal inversion capability up to 1 MHz, while external voltage control of frequency (VCF) accepts 0 V to 10 V input at a 100:1 ratio. This model distinguishes itself by omitting built-in display and frequency counter functions.

Technical Specifications Signal Generation

Waveforms: Sine, Triangle, Square, Ramp, TTL, CMOS

Frequency range: 0.3 Hz to 3 MHz (7 ranges)

Output amplitude: >10 Vpp into 50Ω

Output impedance: 50Ω ±10%

DC offset: -5 V to +5 V (into 50Ω)

Attenuator: Two-step (20 dB × 2) plus variable

Duty cycle: 20% to 80% adjustable, up to 1 MHz maximum

Waveform flatness: <0.3 dB (0.3 Hz–300 kHz), <0.5 dB (300 kHz–3 MHz)

Sine distortion: <2% (0.3 Hz–100 kHz), <5% (100 kHz–3 MHz)

Square wave distortion: <5% (0.3 Hz–100 kHz)

Triangle distortion: <2% (0.3 Hz–100 kHz)

Square wave rise/fall time: ≤25 ns

Pulse wave rise/fall time: ≤100 ns External Control

VCF input: 0 V to 10 V ±1 V (100:1 modulation ratio)

VCF input impedance: 10 kΩ ±10% Physical & Environmental

Power: AC 115 V/230 V ±15%, 50/60 Hz

Dimensions: 251 mm W × 91 mm H × 291 mm D

Weight: 2.0–2.4 kg

Operating temperature: 0°C to 40°C

Storage temperature: -10°C to 70°C

Operating humidity: 80% maximum (non-condensing)

Key Features

Seven overlapping frequency bands eliminate dead zones

Dual output channels: main signal (50Ω) and TTL/CMOS secondary

Variable attenuator plus fixed 20 dB stages for precise amplitude control

Signal inversion on duty cycle-modulated outputs

Low output impedance (50Ω) for direct instrument coupling

Typical Applications

Circuit verification and troubleshooting across audio to RF frequencies

Educational demonstrations of waveform theory and modulation

Component testing requiring variable-frequency stimulus

Equipment calibration using precision waveform references

Compatibility & Integration The 50Ω output impedance enables direct connection to standard test equipment and RF instruments without additional impedance matching. VCF input accommodates external modulation sources for frequency sweep and dynamic control applications. TTL/CMOS outputs interface directly with logic analyzers and digital circuits.

Specifications

ParameterValue
Frequency Range0.3 Hz to 3 MHz | Voltage / Current Range: '-5 V to +5 V DC offset

Instek GFG-8215A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Instek GFG-8215A. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Instek GFG-8215A faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

Instek GFG-8215A price

This Instek GFG-8215A is listed at $185. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Instek GFG-8215A calibration cost

NIST-traceable calibration for the Instek GFG-8215A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents