HP / Agilent 3310B FUNCTION GENERATOR

The HP/Agilent 3310B is a function generator capable of producing sine, square, and triangle waveforms over a frequency range of 0.0005 Hz to 5 MHz. It features adjustable amplitude, DC offset, and duty cycle, making it suitable for a wide range of testing and signal generation applications. The 3310B includes a built-in attenuator and provides both main and auxiliary outputs for versatile connectivity.

Model
HP / Agilent 3310B
Calibration
Available on request
Price
$886
Status
In stock
RFQ ref
3310B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 3310B Function Generator delivers precision waveform synthesis across seven distinct output types: sine, square, triangle, positive pulse, negative pulse, positive ramp, and negative ramp. Operating from 0.0005 Hz to 5 MHz across ten decade ranges, it combines broad frequency coverage with exceptional output control - delivering up to 30 V peak-to-peak (open circuit) or 15 V peak-to-peak (into 50 Ω) on the high output, with minimum outputs below 30 mV peak-to-peak. The instrument features adjustable DC offset (±10 V open circuit, ±5 V into 50 Ω), a built-in attenuator providing >30 dB control, and external VCO capability for frequency modulation and external triggering. Pulse and ramp functions offer fixed 15% or 85% duty cycle operation.

Technical Specifications Frequency Performance

Range: 0.0005 Hz to 5 MHz across 10 decade ranges

Dial accuracy (0.0005 Hz–500 kHz, all functions): ±(1% of setting + 1% of full scale)

Dial accuracy (500 kHz–5 MHz, sine/square/triangle): ±(3% of setting + 3% of full scale)

Dial accuracy (500 kHz–5 MHz, pulse/ramps): ±(10% of setting + 1% of full scale)

Sine response (0.0005 Hz–50 kHz): ±1%; (50 kHz–5 MHz): ±4%

Sine distortion: >40 dB (1%) at 0.0005–10 Hz; >46 dB (0.5%) at 10 Hz–50 kHz (1 kΩ range); >40 dB (1%) at 50–500 kHz; >30 dB (3%) at 500 kHz–5 MHz

Square wave/pulse rise-fall time: <30 ns

Triangle and ramp linearity: 30 V peak-to-peak open circuit; >15 V peak-to-peak into 50 Ω

Pulses >2 MHz: >24 V peak-to-peak open circuit; >12 V peak-to-peak into 50 Ω

Minimum output: <30 mV peak-to-peak open circuit; 30 dB range (>60 dB total across both ranges)

Output impedance: 50 Ω

DC offset: ±10 V open circuit, ±5 V into 50 Ω

Maximum combined AC + DC: ±15 V open circuit, ±7.5 V into 50 Ω External Control

VCO input with 50:1 frequency range on any dial setting

FM capability within 1 to 50× range setting

Key Features

Seven waveform types with fixed pulse/ramp duty cycles (15% or 85%)

Overlapping high and low output ranges for >60 dB total dynamic range

Adjustable DC offset independent of AC amplitude

VCO-based frequency modulation for swept and modulated signal generation

Manual and external triggering support

Typical Applications

Electronic circuit characterization and transient response testing

Audio frequency and ultrasonic signal generation

Frequency sweep and modulation studies

Pulse and timing validation for digital systems

Analog filter and amplifier bench evaluation

Compatibility & Integration External control via VCO input enables integration with control systems and automated test setups. 50 Ω output impedance ensures standard instrument matching.

HP / Agilent 3310B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 3310B. Calibration covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 3310B faults: BNC output connector wear, output amplifier failure from short-circuit drive, display and keypad membrane switch wear, DDS or DAC failure on 33250A. HP 33120A and Agilent 33220A most common fault is BNC output connector wear from repeated cable insertions. Output amplifier failure on the HP 33120A typically results from sustained short-circuit drive. Agilent 33250A DDS and high-speed DAC failures are rare but require component-level repair and post-repair amplitude verification across the full 80 MHz range.

HP / Agilent 3310B price

This HP / Agilent 3310B is listed at $885.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 3310B calibration cost

NIST-traceable calibration for the HP / Agilent 3310B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output amplitude accuracy at 50 ohm and Hi-Z load, DC offset accuracy, symmetry and duty cycle accuracy, and arbitrary waveform sample rate accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →