Rod-L M100BVS5-5.0-25 AC Hipot Test Instrument

The Rod-L M100BVS5-5.0-25 is an AC Hipot Test Instrument designed for electrical safety testing. It applies a high-voltage AC signal to a device under test to verify insulation integrity and detect potential defects. Featuring adjustable voltage and current settings, it ensures accurate and reliable testing. Ideal for quality control and compliance testing in manufacturing and laboratory environments, the M100BVS5-5.0-25 provides essential safety verification.

Model
Rod-L M100BVS5-5.0-25
Calibration
Available on request
Price · starting from
$410
Status
In stock
RFQ ref
M100BVS5-5.0-25
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Rod-L M100BVS5-5.0-25 is an AC Hipot Test Instrument for dielectric withstand and ground continuity testing in manufacturing and laboratory environments. It delivers 0 to 5 kV AC output with adjustable current limits up to 25 mA, meeting UL, IEC, CSA, VDE, FCC, and BSI compliance standards. The instrument features electronically controlled voltage ramp with no spikes, automatic shutdown within 2 milliseconds on breakdown fault, and arc detection down to 10 microseconds.


BV models separate total current from real (resistive) current measurement, eliminating capacitive current from the display.


Technical Specifications



  • Maximum Output Voltage: 0 to 5 kV AC

  • Maximum Output Current: 25 mA (user-adjustable via rear panel control)

  • Test Duration: 1 to 90 seconds (user-selectable), plus two switch-selectable automatic cycles

  • Input Power: 120 V AC

  • Voltage Ramp: Electronically controlled, smooth rise with no spikes

  • Breakdown Fault Shutdown: 2 milliseconds maximum

  • Arc Detection Sensitivity: 10 microseconds minimum

  • Current Measurement: Separate voltage and current metering; BV models display real (resistive) current independent of capacitive current

  • Trip Point Controls: Total current, real current, and under current adjustable

  • Standards Compliance: UL (File E58530 since 1977), IEC, CSA, VDE, FCC, BSI


Key Features



  • Dual-mode fault detection: breakdown monitoring and arc detection

  • Ground continuity monitoring before and during test

  • Leakage current limits preset via rear panel control

  • Audible and visual alarm indication for fault conditions

  • Manual reset requirement for alarms

  • Controlled voltage rate-of-rise prevents damaging spikes

  • Rapid high-voltage deactivation on fault detection


Typical Applications



  • Incoming inspection and quality assurance testing

  • Product development dielectric validation

  • Production line safety compliance verification

  • Cable, connector, and insulation system testing


Compatibility & Integration The M100BVS5-5.0-25 operates on 120 V AC single-phase input. Front panel rise time adjustment is available as Option 03.

Specifications

ParameterValue
Voltage / Current Range0-25 mA, 0-5 kV AC output

Rod-L M100BVS5-5.0-25 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Rod-L M100BVS5-5.0-25. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Rod-L M100BVS5-5.0-25 price

This Rod-L M100BVS5-5.0-25 is listed at $410. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Rod-L M100BVS5-5.0-25 calibration cost

NIST-traceable calibration for the Rod-L M100BVS5-5.0-25 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →