JDS Uniphase Optical Attenuators. Resolution: ** 0.001 dB.

Model
JDS Uniphase MAPA+2319290FP
Calibration
Available on request
Price
$1,950
Status
In stock
RFQ ref
MAPA+2319290FP
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The JDS Uniphase MAPA+2319290FP is a dual optical attenuator cassette module designed for installation in the JDS Uniphase Multiple Application Platform (MAP) chassis. It delivers precise optical signal attenuation across a 45 dB range with exceptional linearity, making it essential for fiber optic communication system testing and measurement. The module integrates a 10/90 coupler that provides a dedicated monitor port, enabling real-time signal observation without compromising main signal integrity.

Technical Specifications

Module Type: Dual Optical Attenuator Cassette

Fiber Type: Multimode (MM) Fiber, 62.5/125 µm core/cladding

Wavelength Range: 750 nm to 1350 nm

Connector Type: FC/PC (all ports)

Attenuation Range: 45 dB

Insertion Loss: 2.2 dB (typical)

Return Loss: 30 dB (typical)

Linearity: ± 0.1 dB

Resolution: 0.001 dB

Key Features

10/90 coupler configuration with integrated monitor port

Precise attenuation control across 45 dB dynamic range

Tight linearity tolerance of ± 0.1 dB ensures repeatable measurements

0.001 dB resolution enables fine-grained signal conditioning

Low insertion loss minimizes signal degradation

FC/PC connectors on all optical ports for reliable interconnection

Typical Applications

Telecommunications network testing and characterization

Data center optical link verification and validation

Research and development in fiber optic systems

Optical component characterization and performance assessment

Compatibility & Integration The MAPA+2319290FP cassette module integrates with JDS Uniphase MAP platform chassis, including the MAP Master Chassis (MAP+2M00) and MAP Benchtop (MAP+2B00) configurations. The module's cassette form factor enables straightforward insertion into compatible MAP slots, supporting modular system expansion and reconfiguration.

Specifications

ParameterValue
Wavelength Range750 nm to 1350 nm

JDS Uniphase MAPA+2319290FP — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase MAPA+2319290FP. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase MAPA+2319290FP faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.

JDS Uniphase MAPA+2319290FP price

This JDS Uniphase MAPA+2319290FP is listed at $1,950. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase MAPA+2319290FP calibration cost

NIST-traceable calibration for the JDS Uniphase MAPA+2319290FP is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →