Agilent Keysight 81570A Optical Attenuator
Agilent / Keysight Optical Attenuators. Accuracy: ±0.1 dB, Resolution: 0.001 dB.
- Model
- Agilent / Keysight 81570A
- Calibration
- Available on request
- Price
- $5,889
- Status
- In stock
- RFQ ref
- 81570A
This unit
The Agilent Keysight 81570A is a variable optical attenuator (VOA) plug-in module engineered for precise optical power control across the Lightwave Solution Platform. Operating from 1200 nm to 1700 nm, it delivers 0–60 dB attenuation with ±0.1 dB accuracy and 0.001 dB resolution. The module handles up to 2 W (+33 dBm) input power and achieves <0.05 dB wavelength flatness across its range.
An internal shutter enables power meter zeroing and protection, while built-in calibration reduces uncertainties in multi-wavelength testing. Low PDL, PMD, and CD characteristics preserve signal integrity. Return loss reaches 45 dB typical.
Designed for single-mode 9/125 µm SMF28 fiber, the 81570A suits optical amplifier characterization, DWDM transmission system testing, and component validation in telecom and data communication environments.
Technical Specifications
- Attenuation range: 0–60 dB
- Attenuation accuracy: ±0.1 dB
- Repeatability: <10 mdB
- Resolution: 0.001 dB
- Wavelength range: 1200–1700 nm (single mode)
- Wavelength flatness: <0.05 dB
- Maximum input power: 2 W (+33 dBm)
- Return loss: 45 dB (typical)
- Fiber type: Singlemode 9/125 µm SMF28
Key Features
- Internal shutter for power meter zeroing and protection
- Built-in calibration capability for multi-wavelength applications
- Low insertion loss with excellent spectral flatness
- Minimal signal distortion from PDL, PMD, and chromatic dispersion
- Straight connector interface
Typical Applications
- Optical amplifier testing (EDFA and Raman amplifiers)
- DWDM transmission system characterization
- Optical network component validation
- Telecommunication and data communication system testing
Compatibility & Integration The 81570A occupies a single slot in Agilent Lightwave Solution Platform mainframes, including the 8163A/B, 8164A/B, and 8166A/B.
Agilent / Keysight 81570A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 81570A. Calibration covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Agilent / Keysight 81570A faults: motor and gear mechanism wear (attenuation steps or loss of smooth control), optical port contamination, EEPROM calibration data corruption. Most common faults are motor or gear mechanism wear on variable attenuators causing attenuation steps or loss of smooth control, optical port contamination reducing dynamic range, and EEPROM calibration data corruption on digitally controlled models.
Agilent / Keysight 81570A price
This Agilent / Keysight 81570A is listed at $5,889. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight 81570A calibration cost
NIST-traceable calibration for the Agilent / Keysight 81570A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers attenuation accuracy at 5 or more set values across the full range (0 to rated maximum dB), attenuation linearity, wavelength-dependent attenuation at 1310 nm, 1490 nm, and 1550 nm, insertion loss at minimum attenuation (0 dB position), and polarization-dependent loss (PDL) where applicable. Turnaround is 1 to 3 business days after receipt. See full calibration details →