Anritsu MS9703B – Optical Spectrum Analyzer

Anritsu Optical Spectrum Analyzers. Dynamic Range: 60 dB.

Model
Anritsu MS9703B
Calibration
Available on request
Price
$2,600
Status
In stock
RFQ ref
MS9703B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9703B is a optical spectrum analyzer engineered for spectral characterization of optical devices and systems in telecommunications environments. It delivers precise measurements across a broad wavelength range with 60 dB dynamic range, enabling accurate evaluation of optical transceivers, lasers, and discrete optical components. The instrument combines intuitive operation with comprehensive analysis functions to streamline spectral data acquisition and signal assessment.

Technical Specifications

Wavelength Range: 1250 nm to 1650 nm

Dynamic Range: 60 dB

Key Features

Broad spectral coverage spanning the C and L bands for extended component characterization

60 dB dynamic range supports detection and measurement of weak and strong signals within the optical spectrum

User-friendly interface reduces setup and measurement time

Comprehensive analysis functions enable detailed spectral feature extraction and optical signal diagnostics

Typical Applications

Optical transceiver validation and characterization

Laser source spectral analysis

Optical component testing and qualification

Telecommunications system development and deployment

Photonics and optical research

Compatibility & Integration The MS9703B integrates within the broader Anritsu optical spectrum analyzer portfolio, offering compatibility with related instruments including the MS9720A, MS9701C, MS9001B1, and MS9740A platforms. This ecosystem supports flexible test configurations for optical communication systems across research, development, and production environments.

Specifications

ParameterValue
Wavelength Range1250 nm to 1650 nm

Frequently Asked Questions

What does the Anritsu MS9703B measure and what is its wavelength range?
The MS9703B is an optical spectrum analyzer designed to measure and characterize optical signals across the C-band and L-band telecommunications windows. It covers a wavelength range of 1250 nm to 1650 nm with a dynamic range of 60 dB, making it suitable for fiber-optic network testing, DWDM system validation, and optical component characterization. This instrument provides real-time spectral analysis critical for telecom infrastructure deployment and maintenance.
What is the condition of this used MS9703B, and what testing was performed?
This Anritsu MS9703B is offered in used condition and has been inventoried as part of our standard receiving procedures. We verify core functionality before listing; however, we recommend independent calibration or factory verification if measurement traceability to NIST standards is required for your application. A full calibration service is available separately to ensure certified accuracy.
What does calibration cover for the MS9703B, and what is the cost?
Calibration service for the MS9703B covers wavelength accuracy and power measurement verification across the 1250–1650 nm range, bringing the instrument into compliance with factory specifications. Our calibration service is available separately starting at $450, and we can provide turnaround estimates upon request. This service includes a calibration certificate documenting traceability and performance metrics.
What interfaces and connectivity options does the MS9703B have?
The Anritsu MS9703B supports GPIB (IEEE 488) for remote instrument control and integration into automated test systems. This interface enables communication with test software, data logging systems, and network analyzers commonly used in optical laboratories and manufacturing environments. Consult the instrument's user manual or contact us for details on specific driver compatibility with your software platform.

Anritsu MS9703B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9703B. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9703B faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.

Anritsu MS9703B price

This Anritsu MS9703B is listed at $2,600. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9703B calibration cost

NIST-traceable calibration for the Anritsu MS9703B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents