Anritsu MS9700A – Optical Spectrum Analyzer
Anritsu Optical Spectrum Analyzers. Accuracy: ** ±20 pm (1520–1620 nm), Bandwidth: ** Minimum 30 pm with selectable resolutions of 0., Dynamic Range: ** ≥60 dB (0.4 nm from peak wavelength).
- Model
- Anritsu MS9700A
- Calibration
- Available on request
- Price
- $1,800
- Status
- In stock
- RFQ ref
- MS9700A
This unit
The Anritsu MS9700A is an Optical Spectrum Analyzer engineered for optical spectrum analysis across R&D, manufacturing, and maintenance applications. It delivers precise wavelength measurement and dynamic range performance critical for optical communication systems, WDM systems, and optical device characterization. The instrument combines high-resolution spectral analysis with fast measurement capabilities, user-configurable bandwidth settings, and multi-connector optical input flexibility to support diverse measurement requirements in laboratory and production environments.
Technical Specifications
Wavelength Measurement Range: 600 nm to 1750 nm (expandable bands available)
Wavelength Accuracy: ±20 pm (1520–1620 nm); ±50 pm (1530–1570 nm)
Resolution Bandwidth: Minimum 30 pm with selectable resolutions of 0.03, 0.05, 0.07, 0.1, 0.2, 0.5, and 1.0 nm
Dynamic Range: ≥60 dB (0.4 nm from peak wavelength)
Optical Reception Sensitivity: –87 dBm noise floor
Measurement Speed: <0.2 s for passive optical devices (5 nm span); up to 0.35 s for 30 nm wavelength sweep in Fast mode
Key Features
Built-in wavelength reference light source for ±20 pm accuracy (1530–1570 nm)
User-replaceable optical connectors: FC, SC, ST, and DIN types
VGA output connector for external display integration
GPIB interface for remote control and automated data transfer
Selectable resolution bandwidth for optimized signal-to-noise performance across measurement ranges
Typical Applications
WDM system validation and troubleshooting
Optical device characterization in R&D environments
Manufacturing quality assurance for optical components
Optical communication system performance analysis
Passive optical device measurement and verification
Compatibility & Integration Multi-connector optical input accommodates standard industry connector types. GPIB control enables integration into automated test systems. VGA output supports real-time waveform monitoring on external displays.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | –87 dBm (noise floor) | Wavelength Range: 600 nm to 1750 nm |
Frequently Asked Questions
- What does the Anritsu MS9700A measure and what is its wavelength range?
- The MS9700A is an optical spectrum analyzer designed to measure optical power across wavelengths from 600 nm to 1750 nm, covering UV through near-infrared regions. It delivers wavelength accuracy of ±20 pm across the 1520–1620 nm band with a minimum 30 pm resolution, dynamic range ≥60 dB, and a noise floor of –87 dBm. This makes it well-suited for fiber-optic characterization, DWDM system analysis, and component testing in telecom and research environments.
- What condition is this Anritsu MS9700A in, and what was verified before listing?
- This unit is offered in used condition. We perform functional verification on all optical spectrum analyzers to confirm operation and measurement capability before listing. Specific wear, cosmetic condition, or service history details are available upon request—contact our team for a detailed unit report.
- Is calibration available for the MS9700A, and what does it cover?
- Yes, calibration is available separately starting at $450 and covers wavelength accuracy and power measurement traceability to NIST standards. We recommend calibration for mission-critical measurements or if the unit has not been serviced recently. Turnaround time and full scope details are provided upon request.
- What interfaces and connectivity options does the MS9700A support?
- The Anritsu MS9700A supports GPIB (IEEE-488.2) and RS-232 interfaces for remote control and data transfer. Compatibility with legacy test automation systems and standard measurement software is confirmed; driver availability and software compatibility details should be verified with our sales team based on your specific integration requirements.
Anritsu MS9700A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9700A. Calibration covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Anritsu MS9700A faults: wavelength motor failure, internal light source dimming, detector sensitivity loss. Common repairs include wavelength motor servicing, internal broadband source replacement, and detector recalibration after extended use.
Anritsu MS9700A price
This Anritsu MS9700A is listed at $1,800. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Anritsu MS9700A calibration cost
NIST-traceable calibration for the Anritsu MS9700A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers wavelength accuracy at 850, 1310, 1550, and 1625 nm, power level accuracy, resolution bandwidth (RBW) accuracy, and dynamic range verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →