Keysight N5183M RF Analog Signal Generator 100 KHz – 20 GHz
Keysight RF Signal Sources. Frequency range: 100 kHz to 20 GHz (extendable to 40 GHz with Optio, Accuracy: ±0.5 dB over specified temperature range, Resolution: 0.1 dB.
- Model
- Keysight N5183M
- Calibration
- Available on request
- Price
- $37,500
- Status
- In stock
- RFQ ref
- N5183M
This unit
The Keysight N5183M MXG ATE is an RF analog signal generator engineered for automated test equipment environments. Operating from 100 kHz to 20 GHz, it delivers calibrated analog signals with maximum output power of +20 dBm and minimum power down to -140 dBm, supporting demanding RF testing across electronic warfare, aerospace, and defense applications.
Technical Specifications
Frequency & Power Performance- Frequency range: 100 kHz to 20 GHz (extendable to 40 GHz with Option B7B doubler or 60 GHz with Option B7C tripler, both requiring Option 542)
- Output power: +20 dBm maximum (typical @ 1 GHz); -140 dBm minimum
- Power accuracy: ±0.5 dB over specified temperature range
- Flatness: ±0.5 dB typical across full frequency band
- Phase noise: -128 dBc/Hz @ 1 GHz, 10 kHz offset; -115 dBc/Hz @ 10 GHz, 10 kHz offset
- Spurious outputs: -30 dBm); <-60 dBc non-harmonics
- THD: <-40 dBc typical; IMD: 70 dB on/off ratio, 10 ns minimum pulse width
- Frequency switching: <1 ms typical (list mode, across 1 GHz bandwidth)
- Amplitude switching: <1 ms typical
- Amplitude resolution: 0.1 dB; Frequency resolution: 0.01 Hz
Key Features
- Type-N female RF connector
- 0.01 Hz frequency resolution for precise tuning
- Rapid sub-millisecond switching for ATE integration
- LAN (LXI Class C), USB 2.0, and optional GPIB interfaces
- 19-inch rack-mountable form factor; approximately 18 kg
Typical Applications Electronic warfare simulation, aerospace defense testing, component characterization, and automated production test environments requiring high-speed frequency and amplitude switching with low distortion.
Compatibility & Integration SCPI, MATLAB, LabVIEW, and Python programming support. Compatible with PathWave Test and VSA software. Powered by 100-240 VAC, 50/60 Hz input; power consumption <400 VA.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 kHz to 20 GHz | Power Range (dBm): '-140 dBm to +20 dBm | Voltage / Current Range: 100-240 VAC, 50/60 Hz |
Keysight N5183M — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keysight N5183M. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keysight N5183M faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Keysight N5183M price
This Keysight N5183M is listed at $37,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keysight N5183M calibration cost
NIST-traceable calibration for the Keysight N5183M is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →