HP / Agilent 83731B 20 GHz Synthesized Signal Generator
HP / Agilent RF Signal Sources. Frequency range: 1.0 to 20 GHz (standard), Accuracy: ±1.3 dB (10–50 MHz).
- Model
- HP / Agilent 83731B
- Calibration
- Available on request
- Price
- $8,064
- Status
- In stock
- RFQ ref
- 83731B
This unit
The HP/Agilent 83731B is a synthesized signal generator delivering precise signal generation from 1 GHz to 20 GHz, with optional extended coverage down to 0.01 GHz. Built for radar, electronic warfare, and communication receiver testing, it combines high spectral purity, sophisticated modulation, and leveled output power control across its operating band.
Technical Specifications Frequency & Output Power
Frequency range: 1.0 to 20 GHz (standard); 0.01 to 20 GHz (optional)
Maximum leveled output power: +13 dBm (0.01–1 GHz), +11 dBm (1–18 GHz), +10 dBm (18–20 GHz)
Minimum leveled output power: -4 dBm (standard); -110 dBm (with Option 1E1)
Output level accuracy: ±1.3 dB (10–50 MHz), ±1.0 dB (50 MHz–20 GHz)
Output level flatness: ±0.5 dB (power ≥ -90 dBm); ±0.7 dB (power < -90 dBm)
Level switching time: <17 ms (without attenuator range change)
Output SWR: <2.0:1 (nominal) Spectral Purity
Harmonics: < -55 dBc (at levels < +6 dBm)
Spurious signals: < -60 dBc
SSB phase noise floor: < -140 dBc/Hz
Residual FM: < 15 Hz (1 GHz, 50 Hz–15 kHz bandwidth, Option 1E5) Pulse Modulation
Rise/fall times: 3 MHz
Pulse on/off ratio: > 80 dB
Maximum leveled output power: -0.5 dB relative to CW Scan & Frequency Modulation
Scan modulation depth: 60 dB log AM; 50 dB step response <5 µs
FM rates: 1 kHz to 1 MHz
Key Features
Pulse modulation for radar and EW receiver simulation
Scan modulation for antenna pattern testing
Frequency modulation for communications data simulation
Leveled output power across full frequency range
Low phase noise performance with fast level switching
Typical Applications
Radar receiver testing and characterization
Electronic warfare receiver validation
Communication system development and verification
Research and manufacturing environments requiring precision signal generation
Compatibility & Integration The 83731B integrates with standard test equipment interfaces and supports extended power and low-noise options via configuration variants.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 1.0 to 20 GHz (standard) |
| 0.01 to 20 GHz (optional) | Power Range (dBm) | '-110 dBm to +13 dBm |
HP / Agilent 83731B — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83731B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83731B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83731B price
This HP / Agilent 83731B is listed at $8,063.8. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83731B calibration cost
NIST-traceable calibration for the HP / Agilent 83731B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →