JDS Uniphase OLP-87

The JDS Uniphase OLP-87 is a handheld optical power meter designed for accurate measurement of optical power in fiber optic systems. It features a wide dynamic range, high accuracy, and a user-friendly interface. Ideal for field technicians and lab use.

Model
JDS Uniphase OLP-87
Calibration
Available on request
Price
$2,100
Status
In stock
RFQ ref
OLP-87
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The OLP-87 (VIAVI) is a handheld optical power meter for field activation, troubleshooting, and maintenance of FTTx/PON networks. It delivers wavelength-selective power measurement across B-PON, E-PON, G-PON, XG(S)-PON, 10G-EPON, and NG-PON2 standards in a single portable unit. Through-mode capability enables simultaneous measurement of voice, data, and RF video signals without breaking the circuit.

Technical Specifications Optical Performance

Downstream wavelengths: 1490 nm, 1550 nm, 1577/1578 nm

Upstream wavelengths (burst mode): 1270 nm, 1310 nm, 1535 nm

NG-PON2 wavelength-selective channels supported per model configuration

Optical return loss: >60 dB

Pass-through insertion loss: 1000

Smart Reporter™ PC software for certification report generation

Hands-free carrier included

Weather-proof, rugged design

Typical Applications

PON network activation and field testing across all major standards

Real-time signal monitoring during troubleshooting and maintenance

Lab and field measurement environments

Fiber end-face quality verification (with optional inspection module)

Compatibility & Integration Supports B-PON, E-PON, G-PON, XG(S)-PON, 10G-EPON, and NG-PON2 (TWDM) networks. Measurement data downloads via USB or Ethernet for post-analysis and documentation.

Specifications

ParameterValue
Wavelength Range1270 nm, 1310 nm, 1490 nm, 1535 nm, 1550 nm, 1577/1578 nm

JDS Uniphase OLP-87 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the JDS Uniphase OLP-87. Calibration covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common JDS Uniphase OLP-87 faults: detector contamination, damaged FC/PC input port, display failure. Common repairs include detector port cleaning or replacement, display repair, and battery or capacitor replacement in older HP/Agilent/Keysight units.

JDS Uniphase OLP-87 price

This JDS Uniphase OLP-87 is listed at $2,100. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

JDS Uniphase OLP-87 calibration cost

NIST-traceable calibration for the JDS Uniphase OLP-87 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. Turnaround is 1 to 3 business days after receipt. See full calibration details →