Anritsu MS9020C Optical Loss Test Set w/ 1 MA9723A Sensor

Anritsu MS9020C Optical Loss Test Set w/ 1 MA9723A Sensor,Optical loss test set with high-sensitivity sensor for precise optical power and loss measurements enhancing test accuracy in fiber optic networks.

Model
Anritsu MS9020C / MA9723A
Calibration
Available on request
Price
$79
Status
In stock
RFQ ref
MS9020C / MA9723A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MS9020C Optical Loss Test Set paired with the MA9723A Sensor delivers precision optical power and loss measurements across fiber optic networks. This integrated platform combines a mainframe optical power meter with a high-sensitivity germanium photodiode sensor, enabling accurate characterization of optical loss, return loss, and power levels across multiple wavelength bands. The system supports continuous wave and modulated light modes, accommodates dynamic ranges exceeding 67 dB with LD light sources, and includes a visible light source for fiber identification and fault location.


Wavelength calibration functionality enables direct absolute-value readings with 5 nm step compensation across three calibration points.


Technical Specifications

Measurement Capability:

  • Optical loss bands: 0.66 µm, 0.85 µm, 1.3 µm, 1.55 µm

  • Measurement modes: Continuous Wave (CW), Modulated Light (270 Hz, 1 kHz, 2 kHz)

  • Optical loss dynamic range: Up to 67 dB (with LD light source)

  • Return loss measurement: 0 to 40 dB at 1.3 µm for single-mode fiber

  • Display resolution: 0.01 dB / 0.1 dB (dBm/dB REL mode); 0.1% to 1% (W/W REL mode)

  • Display units: W, W (REL), dBm, dB (REL), 4-digit format Sensor Specifications (MA9723A):

  • Wavelength range: 0.75 µm to 1.8 µm

  • Measurement range: -60 dBm to +3 dBm (at 1.3 µm, 0° to 40°C)

  • Calibration wavelengths: 0.85 µm, 1.3 µm, 1.55 µm

  • Measurement accuracy: ±5% (at -10 dBm, CW mode)

  • Photodiode element: Germanium (Ge)

  • Active area diameter: 1 mm

  • Connector: FC adapter

  • Dimensions: 30 mm (W) × 30 mm (H) × 37 mm (D)

  • Mass: ≤100 g Environmental & Power:

  • Operating temperature: 0° to +40°C (mainframe), 0° to +50°C (sensor)

  • Storage temperature: -40°C to +70°C

  • Power sources: AC adapter, Ni-Cd battery, UM-3 Alkaline/Manganese batteries

  • Ni-Cd battery runtime: 4 hours (light on), 9 hours (light off); 6-hour charge time

  • Auto power-off: 5 minutes inactivity


Key Features



  • Selectable measurement averaging (On/Off)

  • Visible light source (0.635 µm) for fiber identification and breakpoint detection to 5 km

  • Flickering light function for enhanced visual identification

  • Wavelength calibration with 5 nm step compensation

  • Blanking capability


Compatibility & Integration



  • Sensor connector: FC adapter

  • Mainframe supports FC, ST, DIN, HMS-10/A, and SC connectors via adapter changes

Specifications

ParameterValue
Power Range (dBm)'-60 dBm to +3 dBm (at 1.3 µm, 0° to 40°C) | Wavelength Range: 0.75 µm to 1.8 µm (sensor)

Anritsu MS9020C / MA9723A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MS9020C / MA9723A. Calibration covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MS9020C / MA9723A faults: detector contamination, damaged FC/PC input port, display failure. Common repairs include detector port cleaning or replacement, display repair, and battery or capacitor replacement in older HP/Agilent/Keysight units.

Anritsu MS9020C / MA9723A price

This Anritsu MS9020C / MA9723A is listed at $79. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MS9020C / MA9723A calibration cost

NIST-traceable calibration for the Anritsu MS9020C / MA9723A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity at 850, 1310, 1490, 1550, and 1625 nm, absolute power accuracy, linearity across the full dynamic range, and reference power level. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents