Advantest Q82018A – Advantest Q82018A Optical Sensor
Advantest Optical Power Sensors. Resolution: 0.01 dB, Sensitivity: -60 dBm (at 1.3 µm), Accuracy: ±5%.
- Model
- Advantest Q82018A
- Calibration
- Available on request
- Price
- $1,000
- Status
- In stock
- RFQ ref
- Q82018A
This unit
The Advantest Q82018A is an InGaAs PIN photodiode optical sensor engineered for precision optical power measurement across the long-wavelength infrared spectrum. It delivers sensitivity down to -60 dBm at 1.3 µm, with 0.01 dB power resolution and excellent linearity across a 4-1/2 digit dynamic range. This sensor head integrates with the complete Advantest TQ82000 series optical power meter platform.
Technical Specifications
- Wavelength Range: 0.8 µm to 1.65 µm
- Sensor Type: InGaAs PIN Photodiode
- Measurement Range: -60 dBm to 0 dBm
- Power Resolution: 0.01 dB
- Power Levels: 0.001 µW to 0.001 W
- Sensitivity: -60 dBm (at 1.3 µm)
- Accuracy: ±5%
- Linearity: Excellent
- Dynamic Range: 4-1/2 digits
Key Features
- High sensitivity optical measurements across near-infrared and short-wavelength infrared bands
- ±5% measurement accuracy with 0.01 dB resolution ensures precise characterization of optical power levels
- Excellent linearity performance critical for repeatable, quantifiable results in optical system validation
- Wide 60 dB dynamic measurement range accommodates both weak signals and higher-power optical channels
Typical Applications
- Optical communication system validation and component characterization
- Long-wavelength optical power verification (0.8–1.65 µm band)
- Fiber-optic and integrated photonic device testing
- Optical signal path loss and attenuation measurement
Compatibility & Integration The Q82018A sensor head connects directly to the Advantest optical power meter series: TQ8210, TQ82015, TQ82014A, TQ82017A, TQ82021A, TQ82024, and other TQ82000 series instruments. Operation manual available from Advantest. Connector type specifications available through Advantest sales.
Specifications
| Parameter | Value |
|---|---|
| Power Range (dBm) | '-60 dBm to 0 dBm | Wavelength Range: 0.8 µm to 1.65 µm |
Advantest Q82018A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Advantest Q82018A. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Advantest Q82018A faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.
Advantest Q82018A price
This Advantest Q82018A is listed at $1,000. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Advantest Q82018A calibration cost
NIST-traceable calibration for the Advantest Q82018A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →