Advantest TQ82014

The Advantest TQ82014 is an accessory designed for use with Advantest spectrum analyzers. This component enhances the functionality and precision of spectrum analysis, ensuring accurate measurements and reliable performance in various testing scenarios.

Model
Advantest TQ82014
Calibration
Available on request
Price
$109
Status
In stock
RFQ ref
TQ82014
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest TQ82014 is a single-channel optical power sensor designed as a plug-in accessory for Advantest optical power meters and spectrum analyzers. It extends measurement capability across the visible and near-infrared spectrum, enabling precise optical power characterization in telecommunications, laser printing, optical storage, and R&D environments. The sensor employs a silicon photodiode with onboard wavelength sensitivity compensation, delivering direct absolute power readings with 0.01 dB resolution across a dynamic range spanning six decades.


Technical Specifications



  • Wavelength Range: 0.4 µm to 1.1 µm

  • Power Range: 0.001 µW to 50 mW (−70 dBm to +17 dBm)

  • Power Resolution: 0.01 dB

  • Measurement Accuracy: ±5% nominal; ±3.0% at 780 nm (0 dBm) and ±0.20 dB at 1 mW over 23±3°C; ±4.0% at 780 nm (0 dBm) and ±0.20 dB at 1 mW over 0–40°C

  • Detector: Silicon photodiode

  • Operating Environment: 0–40°C, 4–85% RH

  • Storage Temperature: −25–70°C

  • Dimensions: 90(W) × 94(H) × 6(D) mm

  • Mass: ≤110 g


Key Features



  • Wavelength sensitivity data stored in onboard memory enables automatic compensation when wavelength is set

  • Single-channel architecture optimized for OPM/OSA integration

  • Wide dynamic range measurement from microwatt to tens-of-milliwatt levels

  • Sub-0.01 dB resolution supports precision characterization of laser and optical component performance

  • Silicon photodiode provides flat spectral response across visible and near-IR bands


Typical Applications



  • Optical telecommunications system characterization

  • Laser printer and LED output verification

  • Optical storage media testing (CD, magneto-optical)

  • Research and development optical measurements

  • Production line optical power verification


Compatibility & Integration The TQ82014 connects directly to Advantest TQ8210, TQ8215, Q8214A, and Q8210 optical power meters, as well as select Advantest spectrum analyzers. Wavelength sensitivity at 400 nm may degrade under high-humidity conditions; use in other bands is unaffected by ambient moisture.

Specifications

ParameterValue
Power Range (dBm)−70 dBm to +17 dBm | Wavelength Range: 0.4 µm to 1.1 µm

Advantest TQ82014 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest TQ82014. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest TQ82014 faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.

Advantest TQ82014 price

This Advantest TQ82014 is listed at $109. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest TQ82014 calibration cost

NIST-traceable calibration for the Advantest TQ82014 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →