Advantest R5362B Frequency counter

Advantest Frequency Counters. Frequency Range: Channel 1: 60 mHz to 3 GHz; Channel 2: 200 Hz to 100 MHz, Voltage / Current Range: 3 V maximum input (Channel 1).

Model
Advantest R5362B
Calibration
Available on request
Price
$1,479
Status
In stock
RFQ ref
R5362B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R5362B is a dual-channel frequency counter engineered for precise frequency, period, and time interval measurements across telecommunications, electronics manufacturing, and R&D environments. Channel 1 covers 60 mHz to 3 GHz with 10 mV sensitivity and 50 Ω input impedance; Channel 2 extends from 200 Hz to 100 MHz with 1 MΩ input impedance. Both channels accept 10 mV signals with AC coupling.


The instrument delivers 9-digit resolution at 1-second gate time and completes measurements in 0.08 s cycles.


Technical Specifications

Frequency Measurement

  • Channel 1: 60 mHz to 3 GHz

  • Channel 2: 200 Hz to 100 MHz

  • General counter range: 2 MHz to 3 GHz

  • Sensitivity (both channels): 10 mV

  • Input impedance: Channel 1 50 Ω, Channel 2 1 MΩ

  • Maximum input voltage (Channel 1): 3 V

  • Input attenuation (Channel 1): ×1, ×20

  • Auto-attenuator range: 10 mVrms to 5 Vrms Time Domain & Totalize

  • Period measurement: 10 ns to 5000 s

  • Positive pulse width: 200 ns to 9000 s

  • Totalize function: DC to 50 MHz Performance Metrics

  • Display: 9-digit with 1-second gate

  • Measurement throughput: 0.08 s

  • Time base stability: 0.0000002 /yr

  • External reference: 10 MHz

  • Measurement method: Expanding/reciprocal system

  • Noise reduction: ANS circuit with automatic sensitivity level control


Key Features



  • Dual-channel architecture with independent frequency ranges

  • AC-coupled inputs on both channels

  • Channel 1 provides selectable ×1 or ×20 attenuation

  • Proprietary Advantest counter LSI for expanded measurement capability

  • Integrated cooling fan for sustained operation


Typical Applications Frequency validation in RF and microwave test; period and pulse-width characterization; production-line pass/fail screening with optional TR1644 calculation unit.


Compatibility & Integration Optional interface units enable data output: R13001B (BCD and D/A), R13002B (GPIB and D/A). GPIB interface functions available for remote control and automated test sequences.

Specifications

ParameterValue
Frequency RangeChannel 1: 60 mHz to 3 GHz
Channel 2200 Hz to 100 MHz | Voltage / Current Range: 3 V maximum input (Channel 1)

Advantest R5362B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R5362B. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Advantest R5362B price

This Advantest R5362B is listed at $1,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R5362B calibration cost

NIST-traceable calibration for the Advantest R5362B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents