Agilent / Keysight E1333A 3-Channel Universal Counter
The Agilent/Keysight E1333A is a 3-channel universal counter designed for a wide range of frequency, time, and event counting applications. It offers high resolution and accuracy, making it suitable for R&D, manufacturing, and service environments. This counter features multiple measurement functions, including frequency, period, ratio, time interval, and totalize. It can be integrated into VXI-based test systems for automated testing.
- Model
- Agilent / Keysight E1333A
- Calibration
- Available on request
- Price
- $2,410
- Status
- In stock
- RFQ ref
- E1333A
This unit
The Agilent/Keysight E1333A is a VXI-based 3-channel universal counter module for frequency, time interval, and event counting within automated test systems. It delivers six core measurement functions - frequency, period average, pulse width, time interval, totalize, and ratio - with three input channels supporting multiplexed operation. The module integrates directly into VXI systems for R&D, manufacturing, and service test environments.
Technical Specifications
Measurement Functions- Frequency
- Period Average
- Pulse Width (with Average Mode)
- Time Interval (with Average Mode)
- Totalize
- Frequency Ratio Frequency Measurement
- Maximum frequency: 1 GHz (prescaled by 64 on Channels 1 and 2)
- Range (Channels 1–3): 75 MHz to 1 GHz
- Input coupling: AC coupled
- Input impedance: 50 Ω
- Input range: ±5 Vp
- Sensitivity (75 MHz to 600 MHz): 10 mV
- Dynamic range (75 MHz to 600 MHz): 51 dB Period Average Measurement
- Averages 2^N periods; N range: 1 to 16
- Minimum pulse width: 60 ns
- Resolution: 1 / (10 × 10^6 × 2^N) s Pulse Width Measurement
- Minimum pulse width: 5 ns
- Resolution: (100/2^N) ns; N range: 0 to 7 Time Interval Measurement
- Minimum interval: 200 ns
- Maximum interval: (6871/2^N) s; N range: 0 to 7
- Resolution: (100/2^N) ns Totalizing
- Count range: 1 to (2^36 − 1)
- Minimum pulse width: 5 ns Frequency Ratio Measurement
- Measures ratio between Channels 1 and 2 or Channels 2 and 1
- Resolution: 1/2^N; N range: 6 to 36
- Minimum pulse width: 5 ns Time Base
- Frequency: 10 MHz
- Initial accuracy: 2 ppm
- Aging rate: 2 ppm/year
- Temperature drift: 5 ppm (0 to 50 °C)
Key Features
- Three independent input channels with simultaneous signal conditioning
- Per-channel trigger level and sensitivity controls
- AC-coupled 50 Ω inputs rated ±5 Vp
- Prescaled operation to 1 GHz on all channels
- 10 MHz time base with ±2 ppm initial accuracy
Typical Applications
- Automated frequency and timing measurements in production test
- Multi-channel event counting and pulse characterization
- Ratio and time-interval analysis in systems verification
- Research and service instrumentation requiring VXI integration
Compatibility & Integration
- B-size, 1-slot register-based VXI module
- Compatible with Agilent/Keysight Foundations
- VXI bus interface
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 100 Hz to 100 MHz (Channels 1 & 2, AC coupled) |
| up to 1 GHz (frequency measurement function) | Voltage / Current Range | −2.56 V to 2.54 V (trigger level) |
Agilent / Keysight E1333A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight E1333A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.
Agilent / Keysight E1333A price
This Agilent / Keysight E1333A is listed at $2,410. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Agilent / Keysight E1333A calibration cost
NIST-traceable calibration for the Agilent / Keysight E1333A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →