Keysight (Agilent) U1461A Insulation Multimeter, OLED Display, 50V to 1kV

Keysight / Agilent Insulation Resistance Testers. Voltage: 10 V to 1.1 kV in 1 V steps, Voltage: 0.09% ± 1 digit accuracy, Accuracy: 0.5% ± 1 digit.

Model
Keysight / Agilent U1461A
Calibration
Available on request
Price
$850
Status
In stock
RFQ ref
U1461A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight U1461A Insulation Multimeter combines 4.5-digit digital multimeter functionality with comprehensive insulation resistance testing in a single, field-hardened instrument. Built for predictive and preventive maintenance in electrical and industrial environments, it delivers insulation measurements up to 260 GΩ across test voltages from 50 V to 1 kV, while supporting full DMM measurements with an OLED display rated for 66,000 counts. Safety-rated to CAT III 1000 V / CAT IV 600 V, the U1461A features IP67 sealing and 3-meter drop protection for demanding field deployment.


Technical Specifications

Insulation Resistance Testing

  • Test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

  • Adjustable test voltage: 10 V to 1.1 kV in 1 V steps

  • Measurement range: Up to 260 GΩ

  • Test modes: Timed, Polarization Index (PI), Dielectric Absorption Ratio (DAR)

  • Automatic capacitive discharge and live-circuit inhibit

  • Insulation accuracy (50–250 V): 1.5% ± 5 digits; (500–1000 V): 1.2% ± 5 digits Digital Multimeter Functions

  • DC voltage: 0.09% ± 1 digit accuracy

  • AC voltage (45–65 Hz): 1% ± 3 digits; true-RMS supported

  • DC current (600 µA–440 mA): 0.2% ± 1 digit

  • AC current (600 µA–440 mA): 1% ± 2 digits

  • Resistance: 0.5% to 1.5% ± 2–3 digits depending on range

  • Capacitance: 1% ± 2 digits

  • Frequency: 0.02% ± 1 digit (99.99 Hz–99.99 kHz)

  • Temperature measurement: 1% ± 1 °C

  • Diode test, continuity, and non-contact AC voltage detection (Vsense)

  • Low-pass filter for variable frequency drive measurements Power & Display

  • Four 1.5 V AA batteries

  • Battery life: 50–80 hours (brightness-dependent)

  • 4.5-digit OLED display, 66,000 counts


Key Features



  • Earth bond resistance: 0.5% ± 20 digits (6 Ω range); 0.5% ± 2 digits (60 Ω–60 kΩ)

  • Adjustable DC test voltage accuracy: 0.5% ± 1 digit

  • Safety-rated design prevents testing on live circuits

  • IP67 enclosure, 3-meter drop-proof construction


Typical Applications Predictive maintenance, electrical safety audits, motor winding tests, cable insulation assessment, preventive equipment diagnostics in industrial and commercial facilities.


Compatibility & Integration Optional U1117A Bluetooth adapter enables wireless testing via PC or iOS/Android devices. Automatic test report generation via complimentary reporting software in tabulated or graphical formats.

Specifications

ParameterValue
Frequency Range99.99 Hz to 99.99 kHz | Voltage / Current Range: 10 V to 1.1 kV (adjustable)

Keysight / Agilent U1461A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent U1461A. All calibrations are performed to NIST-traceable standards and ship with a certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Keysight / Agilent U1461A price

This Keysight / Agilent U1461A is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight / Agilent U1461A calibration cost

NIST-traceable calibration for the Keysight / Agilent U1461A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Turnaround is 1 to 3 business days after receipt. See full calibration details →