Keithley 2100/120 – 6½-Digit USB Multimeter

The Keithley 2100/120 is a high-precision 6½-digit USB multimeter, offering accurate voltage, current, resistance, and temperature measurements. It features a broad range of functions, including DC/AC voltage and current, 2- and 4-wire resistance, frequency, and diode testing. Its USB interface allows for easy connectivity to a computer for data logging and control. The multimeter is ideal for benchtop testing, automated testing systems, and educational applications.

Model
Keithley 2100/120
Calibration
Available on request
Price
$575
Status
In stock
RFQ ref
2100/120
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keithley 2100/120 is a 6½-digit USB digital multimeter engineered for high-precision benchtop and automated test system measurements. It delivers 11 primary measurement functions with 8 math capabilities - including RATIO, percentage, Min/Max, NULL, Limits, mX+b, dB, and dBm analysis - supporting diverse electrical characterization workflows. The instrument achieves 0.0038% basic DC voltage accuracy on the 10 V range and 0.013% basic resistance accuracy on the 10 kΩ range, with fully specified accuracies across all functions for ISO-compliant documentation.

Technical Specifications Measurement & Display

6½-digit resolution

11 measurement functions: DC/AC voltage, DC/AC current, 2-wire/4-wire resistance, frequency, continuity, temperature (RTD: PT100, D100, F100, PT385, PT3916), True RMS

8 math functions: RATIO, %, Min/Max, NULL, Limits, mX+b, dB, dBm

Measurement rates: 50 triggered readings/second at 6½ digits via USB; over 2000 readings/second at 4½ digits to internal buffer Electrical Ratings

DC voltage: 0 to 1 kV maximum

AC voltage: 0 to 750 V maximum

DC/AC current: 0 to 3 A maximum

Resistance: 0 to 0.1 GΩ maximum Environmental & Power

Power input: 120 V AC, 50/60 Hz auto-detected

Power consumption: 25 VA

Warm-up requirement: 2 hours for specification compliance

CE compliant, UL listed

Key Features

Selectable front/rear input connectors for flexible test configurations

Rugged construction rated for bench and portable operation

TMC-compliant USB 2.0 interface with SCPI command support

Included LabVIEW driver and Keithley I/O Layer for instrument control

Compatibility & Integration PC software utilities enable direct data integration with Microsoft Excel (Add-In with graphing and settings control) and Microsoft Word (report import). SCPI-compatible programming facilitates automated test sequences and remote data acquisition. USB cable and power cable supplied.

Specifications

ParameterValue
Frequency RangeFrequency measurement: Yes | Voltage / Current Range: 0-1 kV DC, 0-3 A AC/DC, 0-750 V AC

Keithley 2100/120 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keithley 2100/120. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keithley 2100/120 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keithley 2100/120 price

This Keithley 2100/120 is listed at $575. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keithley 2100/120 calibration cost

NIST-traceable calibration for the Keithley 2100/120 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →