Advantest R6581 Digital multimeter

Advantest Laboratory Measurement Instruments. Voltage / Current Range: DC Voltage: 100 mV to 1000 V; DC Current: 100 nA to 1 A; AC Voltage: 10 mV to 1000 V; AC Current: (specified per range).

Model
Advantest R6581
Calibration
Available on request
Price
$2,579
Status
In stock
RFQ ref
R6581
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest R6581 is a precision digital multimeter engineered for high-accuracy measurement across DC and AC domains. It delivers 8.5-digit resolution with True RMS AC capabilities, making it suitable for electronics testing, maintenance, and calibration work. The instrument covers DC voltage (100 mV to 1000 V), DC current (100 nA to 1 A), 2-wire and 4-wire resistance, frequency, and temperature measurements.


Its exceptional DC voltage accuracy - as low as 5 ppm + 0.2 ppm on the 10 V range - and sophisticated 4-wire resistance measurement with selectable source current modes (10 mA down to 100 nA) enable precision characterization of components and circuits. The R6581 incorporates automatic thermoelectromotive force cancellation in resistance mode and achieves low noise performance across all measurement functions at NPLC100 integration.


Technical Specifications

Measurement Functions

  • DC Voltage, DC Current, 2-wire and 4-wire Resistance

  • True RMS AC Voltage and AC Current (Model R6581)

  • Frequency and Temperature

  • Display: 8.5 digits DC Voltage Accuracy (1 year)

  • 100 mV: 7 ppm + 10 ppm

  • 1 V: 6 ppm + 1 ppm

  • 10 V: 5 ppm + 0.2 ppm

  • 100 V: 7 ppm + 1 ppm

  • 1000 V: 7 ppm + 0.2 ppm 4-Wire Resistance Accuracy (1 year)

  • 10 Ω to 100 Ω: 12–14 ppm + 5–20 ppm

  • 1 kΩ: 8 ppm + 0.5 ppm

  • 10 kΩ to 100 kΩ: 15–50 ppm + 2–10 ppm

  • 1 MΩ to 100 MΩ: 50–500 ppm + 10 ppm

  • 1 GΩ: 5000 ppm + 10 ppm Input Characteristics

  • DC Voltage Input Resistance: >10 GΩ

  • 4-Wire Source Current (high power): 10 mA; (low power): 1 mA, 100 µA, 10 µA, 1 µA, 100 nA


Key Features



  • True RMS AC measurement for voltage and current on Model R6581

  • Temperature coefficient: 0.01–1.2 ppm/°C (DC voltage range-dependent)

  • Noise floor at NPLC100: 0.05–0.1 ppm (DC voltage)

  • Automatic thermoelectromotive force cancellation in resistance measurements

  • Burden voltage shunt resistance selectable by current range


Typical Applications Precision component characterization, electrical standards calibration, semiconductor device verification, and high-accuracy circuit troubleshooting.

Specifications

ParameterValue
Voltage / Current RangeDC Voltage: 100 mV to 1000 V
DC Current100 nA to 1 A
AC Voltage10 mV to 1000 V
AC Current(specified per range)

Advantest R6581 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest R6581. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest R6581 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Advantest R6581 price

This Advantest R6581 is listed at $2,579. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest R6581 calibration cost

NIST-traceable calibration for the Advantest R6581 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →