HP / Agilent 83572A RF Plug-In, 26.5-40.0 GHz
HP / Agilent RF Signal Sources. Frequency Range: ** 26.5 GHz to 40.0 GHz, Accuracy: ** 100 MHz.
- Model
- HP / Agilent 83572A
- Calibration
- Available on request
- Price
- $2,570
- Status
- In stock
- RFQ ref
- 83572A
This unit
The HP/Agilent 83572A RF Plug-In extends the frequency coverage of Agilent 8350A or 8350B Sweep Oscillator Mainframes into the millimeter-wave band. Operating from 26.5 GHz to 40.0 GHz with WR-28 waveguide output, this module delivers precise signal generation for advanced RF and microwave applications including millimeter-wave system development, wireless communication testing, and radar system analysis.
Technical Specifications
Frequency Range: 26.5 GHz to 40.0 GHz
Output Connector: WR-28 waveguide
Output Power (Unleveled): Minimum 3 dBm
Output Power (Calibrated Externally Leveled, Option 001): Minimum 2 dBm
Frequency Accuracy: 100 MHz
Output Impedance: 50 ohms (nominal)
Power Control: Manual adjustment to 0.1 dB resolution; remote programmability via HP-IB to 0.01 dB resolution
Key Features
AM/FM/Pulse/Square wave modulation
Power sweep capability for real-time power response measurements
Slope compensation for system and cable loss at high frequencies
External leveling via detector or power meter
Internal modulation option (Option 006): 27.8 kHz for scalar network analyzer interface
Full HP-IB programmability (IEEE-488.1-1987 and IEEE-488.2-1987) for automated testing and remote control
Typical Applications
Millimeter-wave system development
Wireless communication testing
Radar system analysis
Complex RF measurements requiring precise signal generation
Compatibility & Integration Designed as a plug-in module for HP 8350A and HP 8350B Sweep Oscillator Mainframes. Compatible with HP 8756A or HP 8757A Scalar Network Analyzers when Option 006 is installed. Also supports HP 8410 Network Analyzer and R8747B Test Unit for vector network measurements.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 26.5 GHz to 40.0 GHz | Power Range (dBm): 2 dBm to 3 dBm |
HP / Agilent 83572A — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83572A. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common HP / Agilent 83572A faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
HP / Agilent 83572A price
This HP / Agilent 83572A is listed at $2,570.38. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
HP / Agilent 83572A calibration cost
NIST-traceable calibration for the HP / Agilent 83572A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →