HP / Agilent 83630L Synthesized Swept-CW Generator, 10 MHz to 26.5 GHz,+13 dBm calibrated

HP / Agilent RF Signal Sources. Frequency Range: ** 10 MHz to 26.5 GHz, Resolution: ** 1 kHz standard, Resolution: 0.02 dB..

Model
HP / Agilent 83630L
Calibration
Available on request
Price
$17,638
Status
In stock
RFQ ref
83630L
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The HP/Agilent 83630L is a synthesized swept-CW generator delivering precise signal generation across 10 MHz to 26.5 GHz with +13 dBm calibrated output power. Built for microwave component and system testing, it combines wide frequency coverage with analog sweep capability, multiple modulation formats, and step-attenuator support for dynamic range extension to −110 dBm minimum settable output.

Technical Specifications Frequency Range: 10 MHz to 26.5 GHz Output Power: Calibrated at +13 dBm; −110 dBm minimum settable with step attenuator (Option 001). Typical harmonics: −50 dBc below 26.5 GHz. Leveled output power is reduced by 1.5 dB to 20 GHz, 2 dB above 20 GHz, and 2.5 dB above 40 GHz. Temperature specification window: 15 °C to 35 °C (degraded 0.3 dB outside this range). Phase Noise: SSB phase noise <−80 dBc at 10 GHz, 10 kHz offset. Frequency Resolution: 1 kHz standard; 1 Hz with Option 008. Output power resolution: 0.02 dB. Frequency Switching Time: 10 ms typical (without attenuator change). Step sweep switching: 15 ms + (step size/1 GHz) × 5 ms within a frequency band. Temperature Stability: 0.01 dB/°C typical.

Key Features

Analog sweep engine supporting CW, step, list, manual, and ramp sweep modes

Step sweep capability from 2 to 801 points

Wideband FM, linear and log AM, pulse modulation (≥400 MHz), and scan modulation

FSK simulation via external generator

HP-IB (IEEE 488.1) control interface

Coupled attenuator mode operation for leveled output accuracy

Integrated power meter control via 437B for user flatness correction

Typical Applications Microwave component design and verification, communications signal simulation, telemetry tone generation, antenna scanning systems, and radar subsystem testing.

Compatibility & Integration 8510 network analyzer compatibility. Controlled power meter integration supports user-defined flatness correction across the operating band.

Specifications

ParameterValue
Frequency Range10 MHz to 26.5 GHz | Power Range (dBm): '+13 dBm (calibrated)

HP / Agilent 83630L — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the HP / Agilent 83630L. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common HP / Agilent 83630L faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

HP / Agilent 83630L price

This HP / Agilent 83630L is listed at $17,638. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

HP / Agilent 83630L calibration cost

NIST-traceable calibration for the HP / Agilent 83630L is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents