Anritsu 68265B Synthesized Signal Generator

Anritsu RF Signal Sources. Frequency Range: 0.01 GHz to 50 GHz, Resolution: 1 kHz standard.

Model
Anritsu 68265B
Calibration
Available on request
Price
$24,579
Status
In stock
RFQ ref
68265B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu 68265B Synthesized Signal Generator delivers RF and microwave signal generation across 0.01 GHz to 50 GHz with precision output and ultra-low phase noise. Built for high-frequency test environments, this instrument combines fast frequency switching, phase-locked stability, and extensive modulation capability - making it ideal for radar, satellite communications, and telecom applications requiring demanding performance standards.


Technical Specifications



  • Frequency Range: 0.01 GHz to 50 GHz

  • Output Power: –20 dBm to +20 dBm (standard); –10 dBm to +30 dBm (with Option 15B)

  • Phase Noise: Typically –100 dBc/Hz at 10 kHz offset from 10 GHz; downconverter models offer 30–50 dB improvement in the 10 MHz to 2.2 GHz range

  • Switching Time: ≤15 ms + 1 ms/GHz step, or ≤40 ms (whichever is less)

  • Step Sweep: 1 to 10,000 steps; step size 1 kHz to full range (0.1 Hz optional)

  • Dwell Time: 1 ms to 99 seconds per step

  • Frequency Resolution: 1 kHz standard; optional 0.1 Hz

  • Output Impedance: 50 Ohms


Key Features



  • Programmable Frequency Agility: Up to 1,000 non-sequential frequencies via GPIB

  • Alternate Sweep Mode: Dual-range sweep with independent power levels

  • Manual Sweep Mode: Phase-locked stepped frequency adjustment

  • AM Modulation: 0–90% depth, log/linear, DC to 100 kHz rates

  • FM Modulation: Four modes; up to 10 MHz at 8 MHz rates or 100 MHz deviation at 100 Hz rates

  • Phase Modulation (Optional): Up to 400 radians at 1 MHz rates

  • Internal Modulation Generators: Seven waveforms each for AM, FM, and ΦM; optional user-defined complex modulation and AM SCAN (60 dB depth)


Interfaces & Integration



  • GPIB (IEEE-488) for remote control and programming

  • Standard rack-mount form factor for ATE integration

  • Three-wire grounded power input

Specifications

ParameterValue
Frequency Range0.01 GHz to 50 GHz | Power Range (dBm): '-20 dBm to +20 dBm (standard)

Anritsu 68265B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu 68265B. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu 68265B faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu 68265B price

This Anritsu 68265B is listed at $24,579. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu 68265B calibration cost

NIST-traceable calibration for the Anritsu 68265B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →