Yokogawa AQ6151B 900-1700nm Optical Wavelength Meter

The Yokogawa AQ6151B is an optical wavelength meter designed for precise measurement of laser wavelengths in the 900-1700nm range. Ideal for telecommunications, fiber optic testing, and research applications, it offers high accuracy and reliable performance. This instrument ensures accurate wavelength characterization for optical components and systems.

Model
Yokogawa AQ6151B
Calibration
Available on request
Price
$22,980
Status
In stock
RFQ ref
AQ6151B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Yokogawa AQ6151B is a precision optical wavelength meter for the 900-1700 nm range, utilizing a Michelson interferometer and Fast Fourier Transform (FFT) signal processing to deliver high-accuracy wavelength characterization. The instrument measures single and multiple wavelengths simultaneously (up to 1024), with wavelength resolution to 0.0001 nm and measurement times as fast as 0.2 seconds. It accommodates modulated light signals and optical filter characterization, making it suited for telecommunications, fiber optic system validation, and optical component inspection including DFB lasers, tunable lasers, optical transceivers, and WDM transmission systems.


Technical Specifications

Wavelength Measurement

  • Range: 900-1700 nm

  • Accuracy: ±0.2 ppm

  • Resolution: 0.0001 nm

  • Measurement time: 0.2 seconds (fast) or 0.3 seconds (normal)

  • Minimum resolvable separation: 5 GHz or 10 GHz

  • Measurement units: nm, THz, cm⁻¹

  • Frequency bands: O Band, L Band Optical Input

  • Input power range: -40 to 18 dBm

  • Return loss: 35 dB

  • Fiber type: Single Mode (SM, ITU-T G.652) Optical Power Measurement

  • Accuracy: ±0.5 dB (at 1550 nm, -10 dBm)

  • Linearity: ±0.3 dB (at 1550 nm, -30 dBm or higher)

  • Polarization dependence: ±0.5 dB

  • Resolution: 0.01 dB Environmental & Power

  • Operating temperature: 5 to 35 °C

  • Relative humidity: 20 to 80% RH

  • Warm-up time: 60 minutes

  • AC input: 100-240 VAC, 50/60 Hz

  • Power consumption: 100 VA

  • Laser class: CLASS 1


Key Features



  • Simultaneous multi-wavelength measurement capability (up to 1024 wavelengths)

  • Fast measurement cycles support high-throughput testing workflows

  • 5.7-inch color LCD display (640 × 480 dots)

  • Internal memory 256 MB with external USB storage

  • Modulated light signal analysis and optical filter characterization


Interfaces & Compatibility



  • Optical connectors: FC/PC, SC/PC

  • Communication: Ethernet, USB, VGA, GPIB

  • Recalibration interval: 1 year

Specifications

ParameterValue
Power Range (dBm)'-40 to 18 dBm | Voltage / Current Range: 100 VA, 100-240 VAC, 50/60 Hz | Wavelength Range: 900-1700 nm

Yokogawa AQ6151B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ6151B. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Yokogawa AQ6151B faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.

Yokogawa AQ6151B price

This Yokogawa AQ6151B is listed at $22,980. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Yokogawa AQ6151B calibration cost

NIST-traceable calibration for the Yokogawa AQ6151B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents