Yokogawa AQ6150B 900-1700nm Optical Wavelength Meter

Yokogawa Wavelength Meters. Accuracy: ±0.01 nm (typ.), Resolution: 0.001 nm (typ.), Power Range: -70 dBm to +20 dBm.

Model
Yokogawa AQ6150B
Calibration
Available on request
Price
$22,980
Status
In stock
RFQ ref
AQ6150B
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Yokogawa AQ6150B is a precision optical wavelength meter designed for accurate characterization of light sources and components across the 900 nm to 1700 nm spectrum. Built for telecommunications, component manufacturing, and research environments, it delivers wavelength measurements with ±0.01 nm accuracy and 0.001 nm resolution in under half a second per point. The instrument accepts optical signals from -70 dBm to +20 dBm, making it suitable for both weak and moderate-power sources.


Its color LCD touchscreen provides intuitive operation, while USB, LAN, and optional GPIB connectivity enable integration into automated test systems and remote monitoring workflows. Wavelength stability of ±0.005 nm/hour ensures repeatable results across extended measurement sessions.


Technical Specifications



  • Measurement Range: 900 nm to 1700 nm

  • Wavelength Accuracy: ±0.01 nm (typ.)

  • Wavelength Resolution: 0.001 nm (typ.)

  • Measurement Speed: 0.5 seconds/point (max.)

  • Optical Input Power Range: -70 dBm to +20 dBm

  • Wavelength Linearity: ±0.01 nm

  • Wavelength Stability: ±0.005 nm/hour

  • Optical Return Loss: >40 dB

  • Optical Input Connector: FC/APC (standard)

  • Display: Color LCD touchscreen

  • Data Storage: Internal memory, USB flash drive

  • Power Requirements: 100 to 240 VAC, 50/60 Hz

  • Operating Temperature: 0°C to 40°C

  • Operating Humidity: 20% to 80% RH (non-condensing)

  • Dimensions (W × H × D): 250 mm × 100 mm × 320 mm

  • Weight: 4.5 kg


Key Features



  • Submillimeter wavelength accuracy and stability for demanding metrology

  • Rapid single-point measurement capability for production-line integration

  • Wide optical input dynamic range accommodates laser diodes, amplifiers, and attenuated signals

  • FC/APC connector ensures low back-reflection and reliable connections


Typical Applications



  • DWDM and ITU-grid laser testing

  • Semiconductor laser diode characterization

  • Optical amplifier performance evaluation

  • Fiber optic component validation

  • Wavelength-dependent research and development


Compatibility & Integration



  • USB Device interface for direct PC connection

  • LAN (Ethernet) for network integration and remote operation

  • GPIB available as optional interface for legacy automated test equipment

Specifications

ParameterValue
Power Range (dBm)'-70 dBm to +20 dBm | Voltage / Current Range: 100 to 240 Vac, 50/60 Hz | Wavelength Range: 900 nm to 1700 nm

Yokogawa AQ6150B — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Yokogawa AQ6150B. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Yokogawa AQ6150B faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.

Yokogawa AQ6150B price

This Yokogawa AQ6150B is listed at $22,980. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Yokogawa AQ6150B calibration cost

NIST-traceable calibration for the Yokogawa AQ6150B is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents