Burleigh WA-20 Wavemeter

The Burleigh WA-20 Wavemeter is a precision instrument designed for accurate wavelength measurement of continuous wave (CW) lasers. It provides reliable and precise wavelength determination, essential for various scientific and industrial applications.

Model
Burleigh WA-20
Calibration
Available on request
Price
$6,770
Status
In stock
RFQ ref
WA-20
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Burleigh WA-20 Wavemeter is a precision instrument for absolute wavelength measurement of continuous wave lasers across the ultraviolet to mid-infrared spectrum. Built around a scanning Michelson interferometer and an integrated HeNe laser wavelength standard, it delivers traceable measurements without external reference sources. The instrument automatically determines laser wavelength with high accuracy, making it essential for laser tuning, spectral characterization, and drift monitoring applications.

Technical Specifications

Wavelength Range: 0.4 µm to 4 µm (vacuum wavelength measured 0.4 µm to 1 µm)

Measurement Principle: Scanning Michelson interferometer

Internal Calibration: Built-in HeNe laser wavelength standard

Accuracy (High Resolution, linewidth < 2 GHz): 0.4–1.0 µm ±0.001 nm; 1.0–4.0 µm ±0.004 nm

Accuracy (Low Resolution, linewidth < 20 GHz): 0.4–1.0 µm ±0.01 nm; 1.0–4.0 µm ±0.01 nm

Overall Accuracy: ±1 part in 10⁶

Readout Precision: 0.001 nm (high resolution); 0.01 nm (low resolution)

Display Update Rate: Every 1.6 seconds

Power: 110 V, 50/60 Hz, 0.5 A

Dimensions: 17" W × 12" D × 7" H

Manufactured in the United States

Key Features

Automatic wavelength determination eliminates manual calibration overhead

Dual accuracy modes accommodate narrow-linewidth (< 2 GHz) and broader-linewidth (< 20 GHz) laser sources

Sub-picometer readout resolution in high-resolution mode

Real-time display refresh every 1.6 seconds for dynamic measurements

D-sub 25-pin connector for data output and system integration

Typical Applications

Laser wavelength verification and identification

Single-frequency laser characterization

Wavelength drift analysis and stability monitoring

Laser tuning and optimization

Spectroscopic and metrological calibration work

Compatibility & Integration Data output via D-sub 25-pin connector enables instrument integration into automated test systems and data acquisition setups.

Specifications

ParameterValue
Voltage / Current Range0.5 A, 110 V, 50/60 Hz | Wavelength Range: 0.4 µm to 4 µm

Burleigh WA-20 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Burleigh WA-20. Calibration covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Burleigh WA-20 faults: interferometer alignment drift, reference etalon or HeNe laser end-of-life, InGaAs detector sensitivity loss, fiber input connector damage. Fizeau interferometer-based instruments (Agilent 86120B/86122A/C) most commonly develop interferometer alignment drift and InGaAs detector degradation over time. Burleigh WA-series scanning Fabry-Perot instruments most commonly fail due to reference HeNe laser end-of-life. Both types are fully repairable with post-repair wavelength accuracy verification.

Burleigh WA-20 price

This Burleigh WA-20 is listed at $6,770. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Burleigh WA-20 calibration cost

NIST-traceable calibration for the Burleigh WA-20 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers absolute wavelength accuracy at multiple reference points across the full measurement range, frequency accuracy, wavenumber accuracy, and multi-wavelength channel spacing measurement accuracy. Turnaround is 1 to 3 business days after receipt. See full calibration details →