Marconi IFR Aeroflex FS1000 Fast Switching Synthesizer
Marconi / IFR / Aeroflex RF Signal Sources. Frequency Range: 4.5 MHz to 6.01 GHz, Resolution: 2 Hz.
- Model
- Marconi / IFR / Aeroflex FS1000
- Calibration
- Available on request
- Price
- $4,479
- Status
- In stock
- RFQ ref
- FS1000
This unit
The Marconi IFR Aeroflex FS1000 Fast Switching Synthesizer is a RF signal generator engineered for rapid frequency switching and exceptional signal purity in demanding automated test environments. Spanning 4.5 MHz to 6.01 GHz with 2 Hz resolution and sub-100-microsecond switching times, the FS1000 delivers phase noise as low as -145 dBc/Hz across optimized frequency bands. Built for wireless communications, mobile device testing, Bluetooth characterization, radar simulation, and electronic warfare applications, it combines laboratory-grade signal integrity with production-line reliability.
Technical Specifications
Frequency Performance- Frequency Range: 4.5 MHz to 6.01 GHz
- Frequency Resolution: 2 Hz
- Step Size: 2 Hz (4.5 MHz to 4000 MHz), 4 Hz (4000 MHz to 6010 MHz)
- Switching Time: Less than 100 microseconds to within 1.0 radian of final phase
- Switching Time Between Ports: Less than 5 microseconds Signal Purity
- Phase Noise: -130 dBc/Hz at 10 kHz offset (1.0 GHz); -145 dBc/Hz at 50 kHz offset (4.5 to 180 MHz)
- Spurious Levels: Greater than -65 dBc
- Harmonics: -25 dBc maximum
- Residual FM: Less than 7 Hz (4 to 2000 MHz), less than 16 Hz (2000 to 4000 MHz), less than 32 Hz (4000 to 6010 MHz) Output Characteristics
- Output Power: +7 dBm
- Power Flatness: ±1.5 dB
- Output Isolation: 25 dB minimum between ports
- VSWR: 1.8:1
- On/Off Ratio: Greater than 25 dBc External Reference
- Reference Frequency: 10 MHz
- Reference Input Level: +3 dBm ±4 dB
- Reference Output Level: +3 dBm ±2 dB, 50 Ω
Key Features
- Dual-port configuration with independent RF output switching
- Parallel BCD frequency control with strobe and trigger architecture
- Remote RF on/off control and output fault monitoring
- Full 3U rack-mount chassis design
- Mean Time Between Failures exceeding 8,500 hours
Typical Applications Wireless communications systems, mobile network device testing, Bluetooth-enabled product validation, radar simulation, electronic warfare systems, and RF component characterization.
Compatibility & Integration Designed for integration into automated test equipment (ATE) systems requiring deterministic frequency switching and phase-coherent signal generation.
Specifications
| Parameter | Value |
|---|---|
| Frequency Range | 4.5 MHz to 6.01 GHz | Power Range (dBm): '+7 dBm output |
Marconi / IFR / Aeroflex FS1000 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Marconi / IFR / Aeroflex FS1000. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Marconi / IFR / Aeroflex FS1000 faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.
Marconi / IFR / Aeroflex FS1000 price
This Marconi / IFR / Aeroflex FS1000 is listed at $4,479. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Marconi / IFR / Aeroflex FS1000 calibration cost
NIST-traceable calibration for the Marconi / IFR / Aeroflex FS1000 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →