Anritsu MG3693C Microwave Signal Generator 30GHz

Anritsu Signal Generators. Model: MG3693C.

Model
Anritsu MG3693C
Calibration
Available on request
Price
$14,500
Status
In stock
RFQ ref
MG3693C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Anritsu MG3693C is a synthesized signal generator designed for demanding RF and microwave test and measurement applications. It has extensive frequency coverage, precise amplitude control, and high signal purity, making it suitable for a wide range of R&D, manufacturing, and depot repair scenarios.

Technical Specifications Frequency Coverage:

  • 0.1 Hz to 31.8 GHz in a single coaxial output.
  • Extendable to 500 GHz or beyond with external multipliers.
  • Option 22 provides audio frequency coverage from 0.1 Hz to 10 MHz.
  • Frequency resolution down to 0.01 Hz for sweep functions.
  • Frequency resolution of 0.02 Hz for Option 22 below 10 MHz. Output Power:
  • Standard output power specifications are available, with options for higher output.
  • Option 15 provides high power RF components to increase output power levels.
  • With Option 15 and Option 2, output power can range from -120 dBm to +25 dBm.
  • High power output is available, eliminating the need for external amplification.
  • Output power is typically derated by 2 dB when Option 22 is installed. Signal Purity:
  • Industry-best phase noise performance is a key characteristic.
  • Offers three levels of SSB phase noise performance: Standard, Ultra low phase noise (Option 3), and Premium phase noise (Option 3X).
  • Phase noise at 10 GHz with Option 3 can be as low as -115 dBc/Hz at a 100 kHz offset.
  • Spectral purity is a design focus. Modulation Capabilities:
  • Full suite of modulation capabilities for complex signal simulations.
  • Supports AM, FM, Pulse, Scan, Phase, I/Q, Analog, and Wideband FM.
  • Option 28 offers AM, FM, FM, IM modulation.
  • Internal and external AM, FM, Phase, and Pulse modulation are supported for analog signal emulation.
  • Option 27 provides a built-in function and pulse generator.
  • For IQ modulation, an IF input option allows easy up-conversion of an externally IQ-modulated RF signal.
  • Option 20 adds an internal Scan modulator for simulating high-depth amplitude modulated signals.
  • No modulation is available in the 0.1 Hz to 10 MHz band when Option 22 is installed. Switching Speed:
  • Fast switching speed of 5 ms (typical) reduces test time. Sweep Functions:
  • Linear and Logarithmic sweep modes are user-selectable.
  • Step size in log sweep increases logarithmically with frequency.
  • Variable number of steps from 1 to 10,000.
  • Step size can range from 0.01 Hz to the full frequency range of the instrument.
  • Dwell time per step is variable from 1 ms to 99 seconds.
  • Fixed rate sweep allows setting the total sweep time, including lock time, from 20 ms to 99 seconds.
  • Phase-locked control ensures precise frequency control for doubled frequencies.
  • Every frequency step in the sweep range is phase-locked. Interfaces:
  • Intuitive front panel controls for easy operation.
  • Remote control via GPIB (IEEE-488 interface bus) or Ethernet connectivity.
  • All instrument functions, settings, and operating modes are controllable via GPIB commands (Native, SCPI). Time Base:
  • Internal time base can be calibrated to match an external 10 MHz reference.
  • External 10 MHz reference input accepts signals with ±50 Hz tolerance.
  • Option 16 adds an ovenized, 10 MHz crystal oscillator for high-stability time base.
  • Internal time base stability is < 2 x 10–9/day, or < 5 x 10–10/day with Option 16. Physical and Environmental:
  • Dimensions: 429 x 133 x 450 mm.
  • Weight: 18 kg.
  • Operating Temperature Range: 0 °C to +50 °C.
  • Storage Temperature Range: –40 °C to +75 °C.
  • Relative Humidity: 5% to 95% at 40 °C.
  • Altitude: 4,600 meters.
  • EMI: Meets emission and immunity requirements of EN61326: 1998 and EN61000-4-11: 1994.
  • Vibration: Random, 5 Hz - 500 Hz, 0.015-0.0039g²/Hz PSD; Sinusoidal, 5 Hz - 55 Hz, 0.33 mm displacement. Compatibility:
  • Preserves full backward compatibility with Anritsu MG3690A/B series and previous 68C/69B series of RF and microwave signal generators.
  • Drivers are available for MG3690C Series, MG3690B Series, and older models.

Why Choose Aumictech for Anritsu MG3693C?

At Aumictech, we specialize in supplying RF and microwave test equipment. Whether you need frequency coverage, phase noise performance, or advanced modulation capabilities, our team ensures the Anritsu MG3693C delivers maximum performance for your critical applications.

Anritsu MG3693C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Anritsu MG3693C. Calibration covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Anritsu MG3693C faults: YIG oscillator failure (no output or loss of lock), step attenuator wear (output drops or steps at set attenuation), ALC loop failure (uncontrolled output power), I/Q modulator assembly failure. HP/Agilent 836xx series most common faults are YIG oscillator failure and step attenuator contact wear causing output steps or drops at specific attenuation settings. Keysight E4428C/E4438C units most commonly develop ALC loop failure and I/Q modulator assembly faults. YIG oscillator replacement and attenuator service are stocked repairs.

Anritsu MG3693C price

This Anritsu MG3693C is listed at $14,500. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Anritsu MG3693C calibration cost

NIST-traceable calibration for the Anritsu MG3693C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers output frequency accuracy, output power level accuracy across the full frequency range, AM/FM/PM/pulse modulation accuracy, harmonic and spurious output levels, and phase noise floor verification. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents