Keithley DMM7510 7.5 Digit Graphical Sampling Multimeter
The Keithley DMM7510 is a 7.5-digit graphical sampling multimeter that combines high accuracy with high-speed sampling and graphical display capabilities. It features a touchscreen interface for easy navigation and a wide range of measurement functions, including DC voltage, AC voltage, DC current, AC current, resistance, frequency, and temperature.
- Model
- Keithley DMM7510
- Calibration
- Available on request
- Price
- $4,279
- Status
- In stock
- RFQ ref
- DMM7510
This unit
The Keithley DMM7510 is a 7.5-digit graphical sampling multimeter that combines precision DC/AC measurement capabilities with high-speed waveform digitization and touchscreen visualization. Built around an 18-bit digitizer sampling at 1 MS/s, the instrument captures transient events and dynamic signals with 10 nV DC voltage sensitivity and 1 pA DC current sensitivity. The 5-inch color touchscreen with pinch-and-zoom functionality enables intuitive analysis of captured waveforms, making it ideal for characterizing low-power devices and time-domain behavior.
With 14 ppm basic one-year DCV accuracy, selectable 3.5- to 7.5-digit resolution, and internal memory for over 11 million readings (standard mode) or 27.5 million (compact mode), the DMM7510 bridges traditional multimetry and digitization in a single portable platform.
Technical Specifications
Resolution & Display: 3.5- to 7.5-digit selectable. 5-inch capacitive touchscreen, color TFT WVGA (800 × 480) with LED backlight. Digitizer: 1 MS/s sampling rate. 18-bit resolution. Internal memory: >11 million readings (standard) or 27.5 million readings (compact mode). DC Voltage: 10 nV sensitivity. Maximum 1000 V. Selectable input impedance (>10 GΩ || <400 pF or 10 MΩ ±1%). 14 ppm basic one-year DCV accuracy. AC Voltage: True RMS. 0.1 µV ac resolution. Maximum 700 V ac. DC Current: 1 pA sensitivity. Maximum 10 A dc. AC Current: True RMS. 1 nA resolution. Maximum 10 A ac. Resistance: 0.1 µΩ sensitivity. 2- and 4-wire measurement, offset-compensated ohms, dry circuit. Maximum 1 GΩ. Additional Functions: Frequency to 500 kHz. Temperature (RTD, thermistor, thermocouple). Capacitance (1 nF to 1000 µF). Diode and continuity testing. DC voltage ratio. Voltage and current waveform digitization. Environmental: Operating 0°C to 50°C. Relative humidity 0% to 80% non-condensing. 90-minute warmup for specified accuracy. Auto-calibration minimizes temperature and time drift. Power: Battery-powered. Typical battery life 3 years.Key Features
- High-resolution 18-bit digitizer with 1 MS/s capture rate for transient and waveform analysis
- Dual-impedance selectable input for DC voltage (high-impedance or precision 10 MΩ)
- Picoampere-level DC current sensitivity for leakage and low-power device characterization
- 27.5 million reading capacity in compact mode for extended automated test sequences
- Auto-calibration for drift reduction across operating temperature range
- Pinch-and-zoom touchscreen interface for signal exploration
Typical Applications
- Battery and power supply characterization
- Leakage current measurement in semiconductor devices
- Transient capture during power transitions
- Impedance and frequency response analysis
- Temperature monitoring with multiple sensor types
- High-volume production testing with extended data logging
Compatibility & Integration The DMM7510 operates as a standalone portable instrument. Its graphical interface and local storage eliminate dependency on external logging systems for short-duration test campaigns.
Keithley DMM7510 — Repair & Calibration Service
Aumictech offers NIST-traceable calibration and repair for the Keithley DMM7510. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.
Common Keithley DMM7510 faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.
Keithley DMM7510 price
This Keithley DMM7510 is listed at $4,279. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.
Keithley DMM7510 calibration cost
NIST-traceable calibration for the Keithley DMM7510 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →