Advantest TQ82017 Optical power sensor for TQ8210, 0.4 to 1.1 nm, -60 to +17 dBm

The Advantest TQ82017 is an optical power sensor designed for use with the TQ8210 optical power meter. It operates in the 0.4 to 1.1 nm wavelength range and measures optical power from -60 to +17 dBm.

Model
Advantest TQ82017
Calibration
Available on request
Price
$679
Status
In stock
RFQ ref
TQ82017
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Advantest TQ82017 is a silicon-based optical power sensor engineered for precision optical measurements with the Advantest TQ8210 Optical Power Meter. This sensor delivers wide dynamic range performance across -60 to +17 dBm with 0.01 dB resolution and 10 dB range steps across eight measurement ranges. It has measurement accuracy of ±0.15 dB at 780 nm and 0 dBm under controlled conditions, with extended temperature stability across 0 to +40°C operating range.


Technical Specifications



  • Wavelength Range: 0.4 to 1.1 nm

  • Power Measurement Range: -60 to +17 dBm

  • Photoreceptor Element: Silicon (Si)

  • Resolution: 0.01 dB

  • Range Steps: 10 dB steps, 8 ranges

  • Measurement Accuracy: - ±0.15 dB at 780 nm, 0 dBm (23±3°C) - ±3.0% at 780 nm, 1 mW (23±3°C) - ±0.20 dB at 780 nm, 0 dBm (0 to 40°C) - ±4.0% at 780 nm, 1 mW (0 to 40°C)

  • Operating Temperature: 0 to +40°C

  • Storage Temperature: -25 to +70°C

  • Dimensions: 90(W) × 94(H) × 6(D) mm

  • Mass: 110 g maximum


Key Features



  • Eight measurement ranges with 10 dB steps enable flexible dynamic range optimization

  • 0.01 dB resolution supports high-precision optical component characterization

  • Silicon photoreceptor optimized for visible and near-infrared wavelengths

  • Compact form factor (110 g) simplifies test station integration

  • Temperature-rated across industrial operating conditions


Environmental Considerations



  • In humid conditions above 400 nm, wavelength sensitivity may degrade; avoid high-temperature, high-humidity environments for 400 nm measurements

  • Other wavelength bands unaffected by temperature and humidity variations


Compatibility & Integration Connects directly to Advantest TQ8210, TQ8215, and Q8214A Optical Power Meters via standard interface connector.

Specifications

ParameterValue
Power Range (dBm)'-60 to +17 dBm | Wavelength Range: 0.4 to 1.1 nm

Advantest TQ82017 — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Advantest TQ82017. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Advantest TQ82017 faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.

Advantest TQ82017 price

This Advantest TQ82017 is listed at $679. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Advantest TQ82017 calibration cost

NIST-traceable calibration for the Advantest TQ82017 is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →

Documents