Agilent / Keysight 83440C DC-20 GHz Lightwave Converter ,Broad 20 GHz bandwidth (3 dB opt)

Agilent / Keysight Optical Power Sensors. Frequency Range: DC to 20 GHz, Voltage / Current Range: +10 V to +15 V DC, Wavelength Range: 1000 nm to 1600 nm.

Model
Agilent / Keysight 83440C
Calibration
Available on request
Price
$400
Status
In stock
RFQ ref
83440C
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Agilent/Keysight 83440C is a DC-coupled optical-to-electrical converter delivering direct optical-to-electrical signal conversion across DC to 20 GHz. This unamplified InGaAs photodiode probe mounts directly to instrument front panels, eliminating cable-induced signal degradation and distortion. The hermetically sealed detector achieves 22 ps pulse response (FWHM) and operates across the 1000 nm to 1600 nm wavelength range, making it ideal for 1300 nm and 1550 nm applications.


Technical Specifications



  • Bandwidth: DC to 20 GHz (3 dB optical)

  • Photodiode: Hermetically sealed, unamplified InGaAs PIN-diode

  • Pulse Response: 22 ps FWHM

  • Wavelength Range: 1000 nm to 1600 nm

  • Optical Interface: Agilent universal optical interface; compatible with 9/125 µm single-mode fiber

  • Electrical Output: 3.5 mm microwave coaxial connector, 50 Ω unterminated

  • Bias Voltage: +10 V to +15 V DC

  • Power Consumption: < 18 mVA

  • Operating Temperature: 0°C to 55°C

  • Weight: 0.14 kg


Key Features



  • Fast 22 ps pulse response minimizes temporal distortion

  • Low pulse aberrations for accurate waveform capture

  • Integral bias regulation simplifies DC supply requirements

  • Captive RF connector cap protects against ESD at RF pin (200 V susceptibility)

  • Compact probe form factor for direct instrument integration

  • Unamplified detection preserves signal integrity


Typical Applications



  • High-speed optical communication system characterization

  • Laser output performance testing

  • Optical modulator analysis for fiber optic telecommunications


Compatibility & Integration Mounts directly to oscilloscopes, spectrum analyzers, and network analyzers. DC bias cabling options (83440-60004, 83440-60005, 83440-60006) available for power supply integration. AC-coupled instruments require external bias tee (e.g., Agilent 11612A) unless equipped with 50 Ω termination. Optical connector adapters available for non-standard interfaces.

Specifications

ParameterValue
Frequency RangeDC to 20 GHz | Voltage / Current Range: '+10 to +15 VDC | Wavelength Range: 1300 nm, 1550 nm

Agilent / Keysight 83440C — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Agilent / Keysight 83440C. Calibration covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Agilent / Keysight 83440C faults: FC/PC connector damage, EEPROM failure (mainframe shows unrecognized sensor), reduced responsivity. Common faults include FC/PC input connector damage, EEPROM failure causing the module to appear unrecognized by the mainframe, and reduced detector responsivity from contamination.

Agilent / Keysight 83440C price

This Agilent / Keysight 83440C is listed at $399.58. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Agilent / Keysight 83440C calibration cost

NIST-traceable calibration for the Agilent / Keysight 83440C is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers detector responsivity across all specified wavelengths (typically 800-1700 nm range), absolute power accuracy, and EEPROM calibration coefficient update. Compatible with Agilent/HP 8163A/B, 8164A/B, and 8166A/B mainframes.. Turnaround is 1 to 3 business days after receipt. See full calibration details →