Keysight (Agilent) 34410A 6 1/2 Digit High-Performance DMM

Keysight / Agilent Laboratory Measurement Instruments. Resolution: 6.5 digits, Accuracy: DC 0.0030%, Frequency Range: 10 Hz – 20 kHz.

Model
Keysight / Agilent 34410A
Calibration
Available on request
Price
$850
Status
In stock
RFQ ref
34410A
View cart
Prefer to talk? Call +1 (484) 841-9341

This unit

The Keysight (Agilent) 34410A is a 6½ digit benchtop digital multimeter engineered for precision measurement in demanding laboratory and system integration environments. It delivers 0.003% DC accuracy and extends the 34401A platform with faster acquisition rates, expanded memory, and modern connectivity - measuring DC/AC voltage and current, resistance (2-wire and 4-wire), frequency, period, capacitance, temperature, continuity, and diode parameters.


Technical Specifications



  • Resolution: 6.5 digits

  • Basic Accuracy: DC 0.0030%, AC 0.06%

  • Measurement Speed: Up to 1,000 readings/second at 6½ digits (direct to PC), or 10,000 readings/second at 5½ digits

  • Data Logging: 50,000 readings (non-volatile)

  • Voltage Range: DC up to 1000 V, AC up to 750 V (1000 Vpk max)

  • Current Range: Up to 3 A DC or AC, with resolution down to 100 pA at 100 µA range

  • Resistance: Up to 1 GΩ

  • Capacitance: Up to 10 µF

  • Temperature: Up to +600°C (via thermistor or RTD)

  • ACV Frequency Range: 10 Hz – 20 kHz

  • Trigger Performance: Latency <1 µs, jitter <1 µs, bus query response <500 µs

  • Peak Detection: Captures transients as brief as 20 µs


Key Features



  • True RMS AC measurements for accurate non-sinusoidal signals

  • Offset Compensated Ohms for resistance measurement under applied voltage

  • Math and statistical analysis: null, dB, dBm, limits, statistics

  • CAT II (300 V) input protection on main terminals

  • LO-to-ground maximum rating of 500 Vpk


Interfaces & Integration LAN (LXI Class C), USB (High-Speed), and GPIB (IEEE-488) connectivity enable multiple integration paths. Web browser access and SCPI command compatibility support automated test systems. External trigger and measurement complete BNC connectors provide hardware synchronization. LabVIEW, IVI-COM drivers, and Keysight BenchVue compatibility simplify software integration.


Physical 261.2 mm (L) × 303.2 mm (W) × 103.8 mm (H); 3.7 kg.

Specifications

ParameterValue
Frequency Range10 Hz – 20 kHz | Voltage / Current Range: 0-1000 Vdc, 0-3 A AC, 0-3 A DC, 0-750 VAC, 100 pA to 1 GΩ

Keysight / Agilent 34410A — Repair & Calibration Service

Aumictech offers NIST-traceable calibration and repair for the Keysight / Agilent 34410A. Calibration covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. All calibrations ship with a NIST-traceable certificate. Turnaround is typically 1–3 business days after receipt.

Standard Cal
$450
Pass/fail cert + NIST sticker
Cal with Data
$650
Full NIST cert with measured values

Common Keysight / Agilent 34410A faults: blown input fuse, worn input jacks, display segment failure, relay contact wear on bench DMMs. Common faults include worn input jacks (banana socket contact wear on the mA and COM terminals), blown input fuses (especially the 440 mA HRC fuse), and display segment failures. Keithley 2000/2001/2002 bench DMMs commonly develop relay contact wear affecting resistance accuracy after extended service.

Keysight / Agilent 34410A price

This Keysight / Agilent 34410A is listed at $850. Calibration is available separately from $450. Contact us for volume pricing or if you need multiple units.

Keysight / Agilent 34410A calibration cost

NIST-traceable calibration for the Keysight / Agilent 34410A is $450 (standard — pass/fail certificate and calibration sticker) or $650 (full measured data at every test point, reference standards documented, traceability chain included). Calibration for this instrument covers DC voltage accuracy at all ranges, AC voltage (True RMS) accuracy at 50 Hz, 1 kHz, and 10 kHz, DC current accuracy, resistance accuracy at all decade ranges, frequency accuracy, and diode test voltage. Fluke 87V and 289 also include capacitance and temperature calibration.. Turnaround is 1 to 3 business days after receipt. See full calibration details →